User`s guide
Chapter 1 – AT Commands for Remote SIM Application Toolkit
Multi-Tech Systems, Inc. SIM Application Toolkit AT Commands (S000391C) 40
1.5.3.5 AT^SSTR Remote-SAT Event Response – Browser Termination (236)
Write Command
AT^SSTR=236, ,
<TermCause>
Sent by the customer application to indicate that the Internet browser application has
been terminated.
Response
OK
Parameters
<cmdType> 236 – Proactive command ID. See Table 1.
<Term Cause> Unsigned Integer, range 0-255.
Browser Termination Cause.
0 User termination.
1 Error termination.
1.5.3.6 AT^SSTR Remote-SAT Event Response – Terminate Command (254)
Write Command
AT^SSTR=254
This command allows the TA to finish an ongoing proactive command. This is done
by sending repeatedly a terminal response, “ME currently unable to process
command - screen is busy,” to the SIM (see Table 1”) if issued in states PAC or
WAIT. No action is performed if the interface is already in IDLE state. However, the
command returns “OK”.
The reaction to the terminal response depends on the SIM application.
The command can be used to return to IDLE state whether or not a proactive
command is ongoing.
Response
OK
Note
This command is allowed in states IDLE, PAC and WAIT and forces a return to the
IDLE state once it has been issued successfully; i.e., OK response.