Echelon, i.LON, LON, LONORKS, LonTalk, Neuron, LONMARK, 3120, 3150, LNS, LonMaker, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. LonPoint and LonSupport are trademarks of Echelon Corporation. Other brand and product names are trademarks or registered trademarks of their respective holders.
Table of Contents Preface .................................................................................................... iv FCC Compliance Statement – Class B ........................................................... v IC Compliance Statement – Class B......................................................... v VCCI Compliance Statement – Class B ITE............................................. v Welcome..................................................................................................
Preface The i.LON® SmartServer is a low-cost, high-performance controller, network manager, router, remote network interface, and Web server that you can use to connect LONWORKS®, Modbus, and M-Bus devices to corporate IP networks or the Internet.
FCC Compliance Statement – Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause interference with radio communications.
Welcome The SmartServer is a low-cost, high-performance controller, network manager, router, remote network interface, and Web server that you can use to connect LONWORKS , Modbus, and M-Bus devices to corporate IP networks or the Internet. You can connect the SmartServer to a LONWORKS TP/FT-10 channel using the LonTalk connections on the hardware and a high-voltage 100/240V AC mains connection.
The following table lists the SmartServer model numbers, the features included with the model, and the power supply used: Options IP-852 Routing Programming Modem LNS Server 72101R-430 (FT) 72101R-439 (FT) x 72101R-440 (FT) x x 72101R-445 (FT) x x 72102R-430 (FT) x x 72102R-440 (FT) x x x 72102R-445 (FT) x x x x 72103R-430 (PL) 72103R-439 (PL) 72103R-445 (PL) x x x x 72103R-450 (PL) External coupling Note: You can order programming and IP-852 routing licenses for units that do not
• • • • • • • • • • 64 MB SDRAM 64 MB NAND flash memory 2,048 bytes EEPROM 2MB bootROM Extended temperature (-40 to 60°C) for PL model components. External coupling option available for PL model (Model 72103R-420) Carrier detect line for external modems. Reset line to internal modem Improved surge performance Improved RF immunity i.LON SmartServer 2.0 Documentation The documentation for the SmartServer is provided as Adobe Acrobat PDF files and online help files.
• LNS® Programmer’s Guide. Describes how to write LNS applications that take advantage of the network design, installation, maintenance, and control/monitoring capabilities provided by the SmartServer. • OpenLDV™ Programmer’s Guide, xDriver Supplement. Describes how an LNS or OpenLDV application can use the xDriver software to manage communications with multiple LONWORKS networks over a TCP/IP network.
x Region Europe Languages Supported English German French Italian Contact Information Echelon Europe Ltd. Suite 12 Building 6 Croxley Green Business Park Hatters Lane Watford Hertfordshire WD18 8YH United Kingdom Phone: +44 (0)1923 430200 Fax: +44 (0)1923 430300 lonsupport@echelon.co.uk Japan Japanese Echelon Japan Holland Hills Mori Tower, 18F 5-11.2 Toranomon, Minato-ku Tokyo 105-0001 Japan Phone: +81.3-5733-3320 Fax: +81.3-5733-3321 lonsupport@echelon.co.
1 Assembling the SmartServer Hardware This chapter describes how to mount the SmartServer hardware inside a suitable enclosure. It describes how to connect the SmartServer hardware to a power supply; LONWORKS FT-10 and PL-20 channels; digital input, digital output, and pulse meter input devices; and TCP/IP networks. It describes how to connect the SmartServer console port to access its console application. i.LON SmartServer 2.
Assembly Overview You need to assemble the SmartServer and connect it to a TCP/IP network before you can configure it and begin using its embedded applications. This section lists the general steps required to assemble and connect the SmartServer. These steps are then detailed in the referenced sections. 1. Mount the SmartServer inside a suitable enclosure. For more information on this step, see the next section, Mounting the SmartServer. 2. Connect the screw terminals on the SmartServer. a.
b. c. d. Open Internet Explorer 6 or later and enter the following URL: 192.168.1.222. Your SmartServer home page opens. Click the Login button. A login dialog appears. Enter ilon for both the User Name and the Password and then click OK. The i.LON SmartServer 2.0 – Welcome Web page opens. You can configure your SmartServer and begin using its embedded applications as described in the i.LON SmartServer 2.0 User’s Guide.
4 Assembling the SmartServer Hardware
Wiring the SmartServer Connections After you mount the SmartServer, you can wire its connections. The SmartServer has two rows of screw terminals, an RJ-45 10/100 Base T Ethernet port, a DB-9 console port, and an RJ-11 telephone line (SmartServer models 72102). You must connect the power screw terminals for all SmartServer models as described in the Power Supply section.
Connecting the Screw Terminals The SmartServer has two rows of screw terminals located on the top and bottom edges of the enclosure. The screw terminals on the bottom row are numbered 1 to 12 (from left to right), and the screw terminals on the top row are numbered 13 to 28 (from right to left). No that there is no polarity for DC connections. The screw terminals accept 0.22mm – 3.3mm (22 – 12AWG) gauge solid wire. The optimum tightening torque for the screw terminals is 0.75 Newton-meters (6 lbs. in.
! Safety Warning The SmartServer uses a Poly-carbonmonoflouride Lithium Coin battery. RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF UNUSED BATTERIES ACCORDING TO THE INSTRUCTIONS. ! Safety Warning The SmartServer is not equipped with a power disconnect device. When the device is installed and mounted, the installer must provide a means to safely remove power, such as a power switch or a circuit breaker.
The following table lists the enclosure marking for each of the high-voltage AC power mains screw terminals and their connection type. Screw Terminal Enclosure Marking Mains Connection 1 E Earth ground 2 NC Do not connect 3 N Neutral 4 L Line ! Safety and High Voltage Warning Ensure that the AC power mains are turned OFF before removing the cover, handling the mains wiring, or connecting any power mains cabling to the SmartServer device.
! Sicherheitshinweis: Vorsicht Netzspannung! Stellen Sie sicher, daß die Netzspannung ausgeschaltet wurde (Schalterstellung OFF), ehe der Gehäusedeckel entfernt, an der Spannungsversorgung hantiert oder irgendeine Netzverbindung mit dem SmartServer Gerät hergestellt wird. AUF KEINEN FALL darf das SmartServer mit Netzspannungen ausserhalb des Bereichs 100/240V, -10% bis +30%, 50/60Hz±2.5Hz betrieben werden.
The following table lists the enclosure markings for the LONWORKS network screw terminals on the SmartServer and their connection type. Screw Terminal Enclosure Marking ® LONWORKS Network Connection 17 LON B/PLT + TP/FT-10 twisted pair 18 LON®A/PLT - TP/FT-10 twisted pair RS-232/RS-485 Serial Ports The SmartServer includes one RS-232 serial port and one isolated RS-485 multi-drop bus port. The RS-232 serial connection is implemented on screw terminals 21–25.
The following table lists the enclosure markings for the RS-232 and RS-485 port screw terminals and on the SmartServer and their connection types.
Notes: If your external GSM modem requires a carrier detect line, you can attach one end of a 22-gauge (AWG) stranded wire to the carrier detect port on your modem, and then connect the other end of the wire to pin 1 of the RS-232 console port on the SmartServer. If you are connecting an external GSM modem that uses a wireless antenna to your SmartServer, you must install the modem at least 1m away from the SmartServer.
Connecting Legacy or Nonnative Devices to the RS-232 and RS-485 Serial Ports You can connect legacy systems or nonnative networks such as BACnet and CAN (requires an external interface, sold separately) to the SmartServer’s RS-232 and RS-485 serial ports, and use a Freely Programmable Module (FPM) driver for communication between the SmartServer and the devices over the RS-232 or RS-485 serial interfaces. You can create FPM drivers for your SmartServer with Echelon i.LON SmartServer 2.0 Programming Tools.
6 Output 1 Relay output 1 7 Output 2 Relay output 2 8 Output 2 Relay output 2 You can connect the dry contact relay outputs on the SmartServer to a voltage source and a load. When an ON value is asserted, the circuit will be closed and the voltage source will drive the load. The following figure demonstrates this configuration. Pulse Meter Inputs The SmartServer includes two impulse meter inputs that comply with the DIN 43 864 impulse standard (open terminal voltage <12VDC, maximum current ≤27mA).
The following table lists the enclosure markings for the pulse meter input screw terminals on the SmartServer and their connection type.
Digital Inputs The SmartServer has two optically isolated, polarity-sensitive digital inputs that you can use to monitor switch and sensor devices. The digital input connections are implemented on screw terminals 13–16: Input 2 is connected to terminals 13-14; Input 1 is connected to terminals 15–16. These connections are polarity-sensitive: terminals 14 and 16 are marked positive (+), and terminals 13 and 15 are marked negative (-).
+12V <20mA Output Digital Input Connectors +12V < 20mA Output The SmartServer contains one +12VDC outlet that can provide up to 20mA. The +12V <20mA output is implemented on screw terminals 19 and 20. Screw terminal 20 is the +12V <20mA connection. Screw terminal 19 is the system ground. You can connect the +12V <20mA output on the SmartServer to a set of dry contacts in order to power an active device that is connected to the digital input screw terminals.
Connecting the Ethernet Port After you have connected all the required screw terminals on the SmartServer for your system, you may connect the RJ-45 10/100 BaseT Ethernet on the SmartServer to an Ethernet hub or switch that can communicate with your computer. This will connect the SmartServer to a TCP/IP network, and enable you to configure the SmartServer with its built-in Web pages.
Note: Pin 1 of the RS-232 console port can be attached to the carrier detect line of an external GSM modem. Connecting the Telephone Line Port ! Safety Warning The SmartServer’s telephone modem should only be used with telephone circuits equipped with proper lightning and transient protection circuitry. This minimizes the risk of shock or damage should lightning strike on or near a telephone circuit to which the SmartServer is connected. For SmartServer models 72102, which contain a 56K V.
20 Assembling the SmartServer Hardware
2 Using the SmartServer LEDs and Service Buttons This chapter describes how to use the LEDs and service buttons on the SmartServer hardware. i.LON SmartServer 2.
Using the SmartServer LEDs The SmartServer has a number of LEDs that provide status information. The following figure and table display and describes these LEDs. Power/Wink Lights when the SmartServer has power. When the SmartServer receives a LONWORKS wink command, this LED blinks on and off 5 times. When the SmartServer’s applications are not running, this LED blinks rapidly. Service Indicates the state of the LonTalk application in the SmartServer. This LED is normally off.
For PL-20 models of the SmartServer, this LED is the Band In Use (BIU) indicator. It lights whenever there is a signal present on the band that is greater than 80dBµVrms (between 131.5kHz and 133.5kHz). If this LED is on, the SmartServer can not transmit LONWORKS data. LON BIU/RX For FT-10 models of the SmartServer, this LED is the receive transmission (RX) indicator. It lights when the SmartServer receives LONWORKS data. For PL-20 models of the SmartServer, this is the Packet Detect (PKD) indicator.
shortcut menu. The Setup – Reboot dialog opens. Click Reboot to start the reboot. • To reboot your SmartServer using the console application, enter the reboot command. For more information on using the SmartServer Web pages and the console application to reboot the SmartServer, see the i.LON SmartServer 2.0 User’s Guide.
www.echelon.