Specifications
CUSTOMATCOMMANDS
ATCommandsforHSPA‐H5Modem 208
<mode>
0 Disablethesingleeventmonitoring.Default:0.
1 Enablethesingleeventmonitoring.
<paramType> Numericparameterindicatingthetypeofparametercontainedin<param>.
0valueindicatesthat<param>containstheATcommandstringtoexecutewhen
therelatedeventhasoccurred.Othervaluesdependfromthetype
ofevent.
<param>
Numericorstringvaluedependingonthevalueof<paramType>andonthetype
ofevent.
If<paramType>is0,then<param>isastringcontainingtheATcommand:
Ithastobeenclosedbetweendoublequotes
Ithastostartwiththe2charactersAT(orat).
Ifthestringcontainsthecharacter”,thenithastobereplacedwiththe3characters\22.
Themaximumstringlengthis96characters.
Ifitisanemptystring,theATcommandiserased.
If<label>isVBATT,<para mType>canassumevaluesintherange0‐2.
if<paramType>=1,<param>indicatesthebatteryvoltagethresholdintherange0–500,whereoneunit
correspondsto10mV(therefore500correspondsto5V).Default:0.
if<paramType>=2,
<param>indicatesthetimeintervalinsecondsafterthatthevoltagebatteryund erthe
valuespecifiedwith<paramType>=1causestheevent.Therangeis0–255.Default:0.
If<label>isDTR,<paramType>canassumevaluesintherange0‐2.
if<paramType>=1,<param>indicatesthestatushighorlowundermonitoring.Thevaluesare0(low)and1
(high).Default:0.
if<paramType>=2,<param>indicatesthetimeintervalinsecondsafter
thattheDTRinthestatusspecified
with<paramType>=1causes theevent.Therangeis0–255.Default:0
If<label>isROAM,<paramType >canassumeonlythevalue0.Theeventundermonitoringistheroamingstate.
If<label>isCONTDEACT,<paramType>canassumeonlythevalue0.Theeventundermonitoringisthecontext
deactivation.
If<label>isRING,<paramType>can assumevaluesintherange0‐1.
If<paramType>=1,<param>indicatesthenumbersofcallringsafterthattheeventoccurs.Therangeis1‐
50.Default:1.
If<label>isSTARTUP,<paramType>canassumeonly thevalue0.Theeventundermonitoringisthemodule
start‐up.
If<label>isREGISTERED,<paramType>canassumeonlythevalue0.Theeventundermonitoringisthenetwork
registration(tohomenetworkorinroaming)afterthestart‐upandtheSMSordering.
If<label>isGPIOX,<paramType>canassumevaluesintherange0‐3.
if<paramType>=1,<param>indicatestheGPIOpinnumber;supportedrangeisfrom1toavaluethat
dependsonthehardware.Default:1.
if<paramType>=2,<param>indicatesthestatushighor
lowundermonitoring.Thevaluesare0(low)and1
(high).Default:0.
if<paramType>=3,<param>indicatesthetimeintervalinsecondsafterthattheselectedGPIOpininthe
statusspecifiedwith<paramType> =1causestheevent.Therangeis0–255.Default:0.
If<label>isADCH1,<paramType>canassumevaluesintherange0‐3.