User guide
Chapter 1 – Product Description and Specifications
Multi-Tech Systems, Inc. MultiConnect AW User Guide 9
Category Description
Power Requirements* Typical: 0.23A @ 9V @ 2.04W Max: 0.34A @ 9V @ 2.97W
0.12A @ 20V @ 2.31W 0.16A @ 20V @ 3.17W
0.08A @ 32V @ 2.48W 0.11A @ 32V @ 3.34W
9V Peak 1.43A
20V Peak 0.75A
32V Peak 0.50A
Dimensions 7” W x 1.24”H x 2.79”D .78lbs 17.78cmW x 3.15cmH x 7.07cmD 0.320Kg
Operating Temperature** -40° C to +60° C UL listed @ +40° C
Storage Temperature -40° C to +85° C
Humidity Relative humidity 20% to 90% noncondensing
Compliance EMC Compliance
FCC Part 15
EN55022
EN55024
Radio Compliance
FCC Part 22, 24
RSS 132,133
EN301 489-1
EN301 489-7
EN301 511
AS/ACIF S042.1, S042.3
Safety
UL60950-1
cUL60950-1
IEC60950-1
Network Compliance
PTCRB
* Multi-Tech Systems, Inc recommends that the customer incorporate a 10% buffer into their power
source when determining product load.
** UL Listed @ 40°C. Limited by power supply. UL Certification does not apply or extend to an ambient
above 40°C and has not been evaluated by UL for ambient greater than 40°C
** “UL has evaluated this device for use in ordinary locations only. Installation in a vehicle or other outdoor
locations has not been evaluated by UL. UL Certification does not apply or extend to use in vehicles or
outdoor applications or in ambient above 40° C.”
** Optional power must be UL Listed ITE power supply marked LPS or Class 2 rated 9-32Vdc, 1.44 – 0.4A