Specifications

Data/Fax Rack Mounted Modem Card Configuration Guide 7
Chapter 2 Hardware Settings
Setting DIP Switches
The MT5600-V92 modem card contains sixteen DIP switches. How a switch operates depends on whether the
modem is in synchronous or asynchronous mode (DIP switch #12).
Factory defaults are set to use the MT5600BR-V92 to dial up a remote installation where the call is answered
automatically. Your communications software may require different settings. For the correct DIP switch settings,
check your software’s documentation.
Before you install modem cards in the card cage, verify that the DIP switch settings are correct for your
application (dial-up or lease line).
DIP Switches 1-12
*Factory default setting
Switch
Function
Position
Effect
1
DTR Forced/DTR from Interface*
Up*
DTR forced ON at all times
Down
DTR dependent on interface
2
Flow Control &E4*
(Async/Dial-Up/Leased Line)
Up*
Hardware flow control
Down
Software flow control
SDLC*/BSC (Sync)
Up*
SDLC mode
Down
BSC mode
3
Result Codes Enabled*
(Async Dial-up)
Up
Q1 Disable Responses
Down*
Q0 Enable Responses
DbM Transmit -15dB/-11dB*
(Async/Sync/Leased Line)
Up
Lease Line
Down*
Transmits at -11dB
4
Read switches in ASYNC*
Up*
Follows DIP-Switch 6 settings
Ignores switches in ASYNC
Down
Uses stored parameters.
Bypasses DIP-Switch 6 settings
Read switches in SYNC*
(Sync Dial-Up/Leased Line)
Up*
AS/400 Mode OFF
Down
AS/400 Mode ON
5
Auto-Answer Enabled*
(Async/Sync/Dial-Up)
Up*
Enable Auto Answer
Down
Disable Auto Answer
Answer/Originate*
(Async/Sync/Leased Line)
Up*
Answer Mode
Down
Originate Mode
6
Max-Throughput Enabled*
Up*
Compression with error correction
Max - Throughput Disabled
Down
No compression or error correction
Slave Clock Disabled*
(Sync/Dial-Up/Leased)
Up*
Slave Clocking OFF
Down
Slave Clocking ON
7
RTS/Normal/Forced*
(Sync/Async/Dial/Leased)
Up
RTS dependent on interface
Down*
RTS forced ON
8
Command Mode Enabled*
(Sync/Async/Dial/Leased)
Up
Disable Command Mode
Down
Enabled Command Mode
9
No affect