Specifications
Chapter 14 – SIM ToolKit
Multi-Tech Systems, Inc. CDMA AT Commands Reference Guide (PN S000294K) 91
SIM ToolKit Set Facilities +STSF
Description: This command allows SIM ToolKit facilities to be activated, deactivated or configured.
Values: <mode>
0 Deactivates the SIM Toolkit functionalities.
1 Activates the SIM Toolkit functionalities.
2 Configures the SIM Toolkit functionalities.
The activation or deactivation of the SIM Toolkit functionalities requires the use of the +CFUN (Set
phone functionality) command to reset the product. +CFUN is not necessary if PIN is not entered yet.
<Config>
(160060C01F . 5FFFFFFF7F) (hex format)
The <Config> parameter gives the coding of the TERMINAL PROFILE, precisely the list of SIM
Application Toolkit facilities that are supported by the customer application.
<Timeout>
1-255: Timeout for user responses (multiple of 10 seconds).
The <Timeout> parameter (multiple of 10 seconds) sets the maximum time the user has for reacting (to
select an item, to input a text, etc).
<Autoresponse>
0 Automatic response is not activated
1 Automatic response is activated
When the <Autoresponse> is activated, the +STIN indication for Play Tone (5), Refresh (7), Send SS (8),
Send SMS (9) or Send USSD (10) is automatically followed by the corresponding +STGI response.
Note: Some bits are related to the product only and not to the customer application. The product automatically sets
these bits to either 0 or 1 whatever the user enters with the +STSF command. Each facility is coded on 1 bit:
• .bit = 1: facility is supported by the customer application.
• .bit = 0: facility is not supported by the customer application.
Only the first five bytes of the TERMINAL PROFILE (Class 2) can be configured; the other are set to 0.
Syntax: Command syntax: AT+STSF=<mode>[,<config>][,<Timeout>][,<AutoResponse>]
Command Possible Responses
AT+STSF=<Mode>[,<Config>][,<Timeout>][,<AutoResponse>] OK
+CME ERROR: <err>
AT+STSF? +STSF:
<Mode>,<Config>,<Timeout>,<Autoresponse>
Error Codes: +CME ERROR: 3 Operation not allowed. This error is returned when a wrong parameter is entered.
Example:
AT+CMEE=1 Enable the reporting of mobile equipment errors
OK
AT+WIND=15 Set indications
OK
AT+CPAS Query ME Status
+CPAS: 0 ME is ready.
OK
AT+STSF=? Test command SIM ToolKit Set Facilities
+STSF: (0-2), (160060C01F . 5FFFFFFF7F),(1-255)
OK
AT+STSF?
+STSF: 0,”160060C000”,3 No activation of SIM ToolKit functionality
OK
AT+STSF=2,”5FFFFFFF7F” Set all SIM ToolKit facilities (class 3).
OK
AT+STSF=3 Syntax Error
+CME ERROR: 3
AT+STSF=1 Activation of SIM ToolKit functionality
OK
AT+CFUN=1 Reboot Software.
OK
AT+CPIN? Is the ME requiring a password?
+CPIN: SIM PIN Yes, SIM PIN required
AT+CPIN=0000
OK PIN Ok
+WIND: 4 Init phase is complete
AT+STSF?
+STSF: 1,”5FFFFFFF7F”,3 SIM ToolKit functionality activated with all facilities
OK