Specifications

Chapter 21 – AT Command Examples
Multi-Tech Systems, Inc. CDMA AT Commands Reference Guide (PN S000294K) 169
Incoming Voice Call
AT+CLIP=1 Enable incoming caller id presentation
OK
AT+CNUM Display module phone number
+CNUM: “Phone”,”8585551212”,129
OK
…Incoming call…
+RING Incoming call indication
+CLIP: "8585552323",129 Identification of the remote party
ATA Answer the call
OK ATA command is being processed
+WANS Call has been answered
+WCNT:3 Call Connected with CDMA Service Option 3, Traffic channel established
…Conversation…
+WEND:6 Call ended, end reason 6 (Normal Release), call released by the remote party
Call Waiting
ATD8585551212; Make a voice call (final semicolon character required for voice call)
OK ATD Command is being processed
+WORG:8585551212 Indication of call origination sent to the Base Station with dialing string 18001234567
+WCNT:3 Call Connected with CDMA Service Option 3, Traffic channel established.
…Conversation… Conversation with party
+CCWA:”8582701234”,129 Indication of another incoming call, Audio beep sound in the earpiece
AT+WFSH Send a flash to the Base Station (toggle to the second incoming call).
OK AT command is being executed.
+WFSH Flash sent to the Base Station. Call switches to the second call; this is not 100% guaranteed
because the there is no confirmation from the Base Station.
…Conversation… Conversation with party
AT+WFSH Send a flash to the Base Station (toggle back to the first call).
OK AT command is being executed.
+WFSH Flash sent to the Base Station. Call switches to the first call; this is not 100% guaranteed
because the there is no confirmation from the Base Station.
…Conversation… Conversation with party
repeat as necessary
ATH Release all of the calls
OK ATH command is being executed
+WEND:10 Calls End
Originate Data Call
…Host configured… Host application configured for PPP dial up access
ATD#777 Initiate data call (no final semicolon character), number string is carrier specific
CONNECT Data call connected
…PPP negotiation… PPP layer startup and data exchange
…PPP layer shutdown… Host application terminates PPP session
NO CARRIER Data call terminated
AT Module re-enters command mode
OK
Originate Data Call Failure
…Host configured… Host application configured for PPP dial up access
ATD#777 initiate data call (no final semicolon character), number string is carrier specific
Depending on the PPP session failure point, the module may not enter back into command mode until a network server timeout forces
PPP session shutdown. For a broken data pipe situation, the “+++” command can be used to force the module back into command mode.
NO CARRIER Data call terminated
AT Module re-enters command mode
OK