Specifications

Chapter 4 – Serial Interface Control Commands
Multi-Tech Systems, Inc. AT Commands for EDGE (E1) Modems (S000474A) 69
4.8 AT+ILRR Set TE-TA Local Rate Reporting
Description: AT+ILRR controls whether or not the intermediate result code “+ILRR” is transmitted from the TA
to the TE while a connection is being set up. The result code indicates the local rate. It is issued
before the final result code of the connection; e.g., CONNECT is transmitted to the TE.
Syntax: Test Command: AT+ILRR=?
Response: +ILRR: (list of supported <value>s)
OK
Read Command: AT+ILRR?
Response: +ILRR: <value>
OK
Write Command: AT+ILRR=<value>
Response: OK
ERROR
+CME ERROR: <err>
Intermediate Result Code: +ILRR: <rate>
Indicates local port rate setting upon connection setup.
Parameters:
<value> Value can be stored with AT&W.
Value can be displayed with AT&V.
0 Disables reporting of local port rate. Default (Factory default).
1 Enables reporting of local port rate
<rate> Port rate setting upon connection setup (bps)
0 Autobauding (see Section 4.9.1, Autobauding).
300
600
1200
2400
4800
9600
14400
19200
28800
38400
57600
115200
230400
460800
Notes:
This command is PIN protected.
This command is supported in airplane mode.