Specifications

Chapter 2 – Configuration Commands
Multi-Tech Systems, Inc. AT Commands for EDGE (E1) Modems (S000474A) 35
Write Command for URC Indication in Datamode via Ring Line:
AT^SCFG=”URC/Datamode/Ringline”[, <udri>]
Responses: ^SCFG: “URC/Datamode/Ringline”, <udri>
OK
ERROR
+CME ERROR: <err
Write Command for URC Indication via Ring Line:
AT^SCFG=”URC/Ringline”[, <uri>]
Responses: ^SCFG: “URC/Ringline”, <uri>
OK
ERROR
+CME ERROR: <err
Write Command for Duration of Active RING Line for URC Indications:
AT^SCFG=”URC/Ringline/ActiveTime”[, <urat>]
Responses: ^SCFG: “URC/Ringline/ActiveTime”, <urat>
OK
ERROR
+CME ERROR: <err
Unsolicited Result Code
URC 1
^SCFG: "AutoExec", <AutoExecState>, <AutoExecType>, <AutoExecIndex>,
<AutoExecMode>, <AutoExecATC>
If the event specified with <AutoExecType> occurs and the related AT command line is executed
this URC is issued.
^SYSSTART AIRPLANE MODE
This URC is issued each time the Airplane mode is activated, no matter whether Airplane mode
is set with parameter <map>="on" or <mapos>="on". The URC notifies the user that only the AT
commands supported in Airplane mode are accessible. After leaving the Airplane mode the URC
"^SYSSTART" indicates that the ME has returned to Normal mode and the full set of AT
commands is accessible again.
Parameter Descriptions:
<AutoExecCmd> AutoExec Command
This parameter serves to switch the Autoexec function on or off.
If it is switched off (<AutoExecCmd>=0), parameters following
<AutoExecIndex> are ignored and all settings at the given index are restored
to their default values.
Value will be saved while switching off the module via AT commands (e.g.,
AT+CFUN or AT^SMSO) and restored on next power up.
0 Disable automatic execution of the AT command(s) specified with
<AutoExecATC> at a given <AutoExecIndex>.
1 Enable automatic execution of the AT command(s) specified with
<AutoExecATC> at a given <AutoExecIndex>. Not allowed for
<AutoExecType>=0 (DTR line activation) while multiplex mode is active,
refer to AT+CMUX.
<AutoExecType> AutoExec Event Type
This parameter selects the kind of event used to automatically launch the AT
command(s) specified with <AutoExecATC>.
Value will be saved while switching off the module via AT commands (e.g.,
AT+CFUN or AT^SMSO) and restored
on next power up.
0 Autoexec activity is driven by ASC0 DTR line activation (OFF-ON
transition).
1 Autoexec activity is timer driven. To specify the time span use
<AutoExecPeriod>.