Specifications
Chapter 18 – Miscellaneous Commands
Multi-Tech Systems, Inc. AT Commands for EDGE (E1) Modems (S000474A) 282
Chapter 18 – Miscellaneous
Commands
The AT Commands described in this chapter are related to various areas.
18.1 A/ Repeat Previous Command Line
Description: Repeat previous command line.
Syntax: Exec Command: A/
Response: NA
Notes:
• Line does not need to end with terminating character.
• After beginning with the character “a” or “A” a second character “t”, “T” or “/” has to follow. In case of using a
wrong second character, it is necessary to start again with character “a” or “A”.
• If autobauding is active, the command A/ cannot be used (see AT+IPR).
• This command is not PIN protected.
• This command is supported in airplane mode.
18.2 ATS3 Set Command Line Termination Character
Description: The ATS3 command determines the character recognized by the TA to terminate an incoming
command line. It is also generated for result codes and information text, along with the ATS4
parameter.
Syntax: Read Command: ATS3?
Response: <n>
OK
Write Command: ATS3=<n>
Response: OK
ERROR
Parameter:
<n> This parameter can be stored with AT&W and can be displayed with AT&V.
Command line termination character
000.....127 Default = 13. This is the factory default value and can be restored to '13' with AT&F.
Notes:
• Using a value other than the default 13 may cause problems when entering commands.
• Whenever you change the setting, take into account that the new value has no effect on the URC
“^SHUTDOWN”.
• This command is not PIN protected.
• This command is supported in airplane mode.