Specifications
Chapter 2 – Configuration Commands
Multi-Tech Systems, Inc. AT Commands for EDGE (E1) Modems (S000474A) 22
2.6 ATX Set CONNECT Result Code Format and Call
Monitoring
Description: ATX determines whether or not the TA (terminal adapter) detects the presence of dial tone and
busy signal and whether or not the TA transmits particular result codes.
Syntax: Exec Command: ATX[<value>]
Response: OK
ERROR
Parameter: <value>
0 CONNECT result code only returned, dial tone and busy detection are both
disabled. Default value if the parameter is omitted (0 will be assumed).
1 CONNECT <text> result code only returned, dial tone and busy detection are
both disabled.
2 CONNECT <text> result code returned, dial tone detection is enabled, busy
detection is disabled.
3 CONNECT <text> result code returned, dial tone detection is disabled, busy
detection is enabled.
4 CONNECT <text> result code returned, dial tone and busy detection are both
enabled. Factory default value; will be restored to 4 with AT&F.
Notes:
• This command is not PIN protected.
• This command is supported in airplane mode.
• Store the parameters with the AT&W command.
• Display the parameters with the AT&V command.
2.7 AT\ V Set CONNECT Result Code Format
Description: This command sets the CONNECT result code format.
Syntax: Exec Command: AT\ V[<value>]
Response: OK
ERROR
Parameter: <value>
0 CONNECT <text> result code returned without RLP trailer. Default value if the
parameter is omitted (0 will be assumed).
1 CONNECT <text> result code returned with RLP trailer. Factory default value;
will be restored to 1 with AT&F.
Notes:
• For circuit-switched data calls only
• Output only if ATX parameter is set with value > 0.
• This command is not PIN protected.
• This command is supported in airplane mode.
• Store the parameters with the AT&W command.
• Display the parameters with the AT&V command.