Specifications
Chapter 7 – Call-Related Commands
Multi-Tech Systems, Inc. AT Commands for EDGE (E1) Modems (S000474A) 111
Notes:
• The command must be set before the call comes. By default, when you do not modify the settings, all calls
received without bearer element are assumed to be voice.
• If problems are encountered with CSD connections at 14.4 kbit/s you may be required to change the Fixed
Network User Rate depending on the network. See AT^SFNUR for details.
• This command is not PIN protected.
• This command is supported in airplane mode.
7.27 AT^SCNI List Call Number Information
Description: TA returns a list of current calls of ME.
Syntax: Test Command: AT^SCNI=?
Response: OK
Exec Command: AT^SCNI
Response: ^SCNI: <id>1[,<cs>[,<number>,<type>]]
^SCNI: <id>2[,<cs>[,<number>,<type>]]
[...]
OK
ERROR
+CME ERROR: <err>
Parameter:
<id>
Call identification number; this number can be used in AT+CHLD command operations.
1...7
<cs>
Call status of respective call number (first parameter)
0 call hold
1 call in progress
2 waiting call
<number>
string type phone number in format specified by <type>
<type>
type of address octet in integer format
145 when dialing string includes international access code character “+”
128 when the number is restricted
129 otherwise
Notes:
• See also AT+CLCC
• This command is PIN protected.
• This command is not supported in airplane mode.
7.28 AT^SLCD Display Last Call Duration
Description: TA returns last call duration or current call duration.
Syntax: Test Command: AT^SLCD=?
Response: OK
ERROR
+CME ERROR: <err>
Exec Command: AT^SLCD
Response: ^SLCD: <time>
OK
ERROR
+CME ERROR: <err>
Parameter:
<time>
Format is “hh:mm:ss”, where characters indicate hours, minutes, seconds; e.g., 22:10:00 “22:10:00”
Max value is 9999:59:59
Notes:
• The proper working of that command is network dependent.
• This command is PIN protected.
• This command is supported in airplane mode.