Specifications

Chapter 7 – Call-Related Commands
Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 90
7.24 AT+CRC Set Cellular Result Codes for
Incoming Call Indication
Description: The AT+CRC command controls whether or not to use the extended format of incoming
call indication.
<mode>=1 may lead to a connection failure if the application (e.g., WinFax) waits for the
default URC.
Test Command Syntax: AT+CRC=?
Response: +CRC: (list of supported<mode>s)
OK
ERROR
Read Command Syntax: AT+CRC?
Response: +CRC: <mode>
OK
ERROR
Write Command Syntax: AT+CRC=[<mode>]
Response: OK
ERROR
Parameter Descriptions:
<mode>
0 Disable extended format. Default.
1 Enable extended format
<type>
“REL ASYNC“ Asynchronous non-transparent
“FAX“ Facsimile
“VOICE“ Voice
“GPRS“ <PDP_type>, <PDP_addr> [,[<L2P>][,<APN>]] GPRS network request for PDP context activation
Unsolicited Result Codes:
URC 1
RING
Indicates incoming call to the TE if <mode>=0.
URC 2
+CRING: <type>
Indicates incoming call to the TE if <mode>=1.
7.25 AT+CSNS Single Numbering Scheme
Description: The AT+CSNS command enables the ME to accept incoming calls when no bearer
capability information is provided with the call; e.g., single numbering scheme calls or calls
originitating from analog devices.
Test Command Syntax: AT+CSNS=?
Response: +CSNS: (list of supported<mode>s)
OK
Read Command Syntax: AT+CSNS?
Response: +CSNS: <mode>
OK
Write Command Syntax: AT+CSNS=[<mode>]
Response: OK
ERROR
+CME ERROR
Parameter Description:
<mode>(num)
0 Voice: Each call received without bearer element is assumed to be speech. Default.
2 Fax: Each call received without bearer element is assumed to be an incoming fax.
4 Data: Each call received without bearer element is assumed to be a data call.
Please take into account that the bearer service parameters set with AT+CBST apply to all data
calls including those received without bearer capability.
Notes:
The command must be set before the call comes. By default, when you do not modify the settings, all calls
received without bearer element are assumed to be voice.
The setting will be automatically saved when you power down the GSM engine with AT^SMSO, provided that
PIN authentication has been done. This value will be restored when PIN authentication is done again.