The AT Commands described in this chapter are related to various areas.
19.1 A/ Repeat Previous Command Line
Description: Repeat previous command line.
Exec Command Syntax: A/
Response: NA
Notes:
• Line does not need to end with terminating character.
• After beginning with the character “a” or “A” a second character “t”, “T” or “/” has to follow. In case of using a
wrong second character, it is necessary to start again with character “a” or “A”.
• If autobauding is active, the command A/ cannot be used (see AT+IPR).
19.2 ATS3 Set Command Line Termination
Character
Description: The ATS3 command determines the character recognized by the TA to terminate an
incoming command line.
Read Command Syntax: ATS3?
Response: <n>
OK
Write Command Syntax: ATS3=<n>
Response: OK
ERROR
Parameter Description:
<n>
Command line termination character
000.....127 Default = 13.
Notes:
• Using a value other than the default 13 may cause problems when entering commands.
• Whenever you change the setting, take into account that the new value has no effect on the URC
“^SHUTDOWN”.
19.3 ATS4 Set Response Formatting Character
Description: The ATS4 command determines the character generated by the TA for result code and
information text.
Read Command Syntax: ATS4?
Response: <n>
OK
Write Command Syntax: ATS4=<n>
Response: OK
ERROR
Parameter Description:
<n>
Response formatting character
000....127 Default = 10
Note:
Whenever you change the setting take into account that the new value has no effect on the URC