Specifications
CUSTOMATCOMMANDS
HSPA+ATCommandsReferenceGuide 206
AT#ENAEVMONI? Read
AT#ENAEVMONI=? Test
ParametersandValues
<mod>
0 Servicedisabled.Default:0.
1 Serviceenabled.
Note:WhentheserviceisactiveonaspecificATinstance,thatinstancecannotbe
usedforanyotherscope,exceptforOTAservicethathasthehighestpriority.For
exampleinthemultiplexerrequesttoestablishtheinstance,therequestis
rejected.
Notes
Thecurrentsettingsarestoredinnon‐volatilememory.
EvMoniServiceParameter#ENAE VMONI CFG
SetcommandconfigurestheEvMoniservice.
Readcommandreturnsthecurrentsettingsofparametersintheformat:
#ENAEVMONICFG:<instance>,<urcmod>,<timeout>
TestcommandreturnsthesupportedvaluesfortheENAEVMONICFGparameters
Syntax
Command Commandtype
AT#ENAEVMONICFG=<instance>[,<urcmod>[,<timeout>]] Set
AT#ENAEVMONICFG? Read
AT#ENAEVMONICFG=? Test
ParametersandValues
<instance> ATinstanceusedbytheservicetoruntheATcommand.Range2‐3.Default:3.
<urcmod>
0 Disableunsolicitedmessage.
1
EnableanunsolicitedmessagewhenanATcommandisexecutedafteraneventis
occurred.Default:1.
Whenunsolicitedisenabled,theATcommandisindicatedtoTEwithuns
olicited
resultcode:
#EVMONI:<Text>
Forexample:
#EVMONI:AT+CGMR;+CGSN;+GSN;+CCLK
Unsolicitedisdumpedontheinstancethatrequestedtheserviceactivation.
<timeout>
Definesinminutesthemaximumtimeforacommandexecution.Iftimeout
expiresthemoduleisrebooted.Default:5.
Notes
Thecurrentsettingsarestoredinnon‐volatilememory.