Specifications
CUSTOMATCOMMANDS
HSPA+ATCommandsReferenceGuide 182
ClockManagement#CCLK
Setcommandsetsthereal‐timeclockoftheME.
Readcommandreturnsthecurrentsettingofthereal‐timeclock,intheformat<time>.
TestcommandreturnstheOKresultcode.
Syntax
Command Commandtype
AT#CCLK=<time> Set
AT#CCLK? Read
AT#CCLK=? Test
ParametersandValues
<time> Currenttimeasquotedstringintheformat:"yy/MM/dd,hh:mm:ss±zz,d".
yy Year.Twolastdigitsaremandatory.Rangeis00‐99.
MM Month.Twolastdigitsaremandatory.Rangeis01‐12.
dd Day.Twolastdigitsaremandatory.
Therangefordd(day)dependsonthemonthandtheyearitrefersto.Available
rangesare
:
(01‐28)
(01‐29)
(01‐30)
(01‐31)
Tryingtoenteranoutofrangevalueraisesanerror.
hh Hour.Twolastdigitsaremandatory.Rangeis00‐23.
mm Minute.Twolastdigitsaremandatory.Rangeis00‐59.
ss Seconds.Twola
stdigitsaremandatory.Rangeis00‐59.
±zz
Timezone.Indicatesthedifference,expressedinquarterofanhour,betweenthe
localtimeandGMT.Twolastdigitsaremandatory.Rangeis‐47to+48.
d
Numberofhoursaddedtothelocaltimezonebecauseofdaylightsavingstime
adjustme
nt.Rangeis0‐2.
Notes
IfthetimeissetbythenetworkbuttheDSTinformationismissing,orthetimeissetby+CCLKcommand,then
the<time>formatis:"yy/MM/dd,hh:mm:ss±zz"
Examples
AT#CCLK="02/09/07,22:30:00+04,1"
OK
AT#CCLK?
#CCLK: 02/09/07,22:30:25+04,1
OK
EnhancedNetworkSelection#ENS
SetcommandactivatestheENSfunctions.