Specifications
CUSTOMATCOMMANDS
HSPA+ATCommandsReferenceGuide 154
Notes
ThealarmmodeisindicatedbystatusONofhardwarepinCTSandbystatusONofpinDSR.Thepowersaving
statusisindicatedbyaCTS‐OFFandDSR‐OFFstatus.ThenormaloperatingstatusisindicatedbyDSR‐ON.
Duringthealarmmodethedevicedoesnotmakeanynetworkscananddoesnotregistertoanynetwork.
Therefore,thedevicecannotdialorreceiveanycallorSM.Theonlycommandthatcanbeissuedtothemodule
inthisstateis#WAKE.Everyothercommandmustnotbeissuedduringthisstate.
Temperat ureMonitor#TEMPMON
Setcommandsetsthebehaviorofthemoduleinternaltemperaturemonitor.
Readcommandreportsthecurrentparametersettingsfor#TEMPMONcommandintheformat:
#TEMPMON:<urcmode>,<action>[,<hyst_ti me>[,<GPIO>]]
Testcommandreportsthesupportedrangeofvaluesforparameters<mod>,<urcmode>,<action>,<hyst_time>
and<GPIO>
Syntax
Command Commandtype
AT#TEMPMON=<mod>[,<urcmode>[,<action>[,<hyst_time>[,<GPIO>]]]] Set
AT#TEMPMON? Read
AT#TEMPMON=? Test
ParametersandValues
<mod>
0 Setsthecommandparameters.
1
Triggersthemeasurementofthemoduleinternaltemperature,reportingthe
resultintheformat:
#TEMPMEAS:<level>,<value>
where:
<level>‐Thresholdlevel
‐2‐Extremetemperaturelowerbound.Fordetails,seetheNotessection.
‐1‐Operatingtemperaturelowerbound.Fordetails,seetheNotessection.
0‐Normalte
mperature
1‐Operatingtemperatureupperbound.Fordetails,seetheNotessection.
2‐Extremetemperatureupperbound.Fordetails,seetheNotessection.
<value>‐ActualtemperatureexpressedinCelsiusdegrees.
<urcmode> <urcmode>‐URCpresentationmode.
0 DisablesthepresentationofthetemperaturemonitorURC
1
Enablesthepresentationofth
etemperaturemonitorURC,wheneverthemodule
internaltemperaturereacheseitheroperatingorextremelevels;theunsolicited
messageisintheformat:
#TEMPMEAS:<level>,<value>
where:
<level>and<value>areasbefore
<action>
Sumofintegers,eachrepresentinganactiontobedonewheneverthemodule
internaltemperaturereacheseitheroperatingorextremelevelsDefault:0.
If<actio
n>isnotzero,itismandatorytosetthe<hyst_time>parametertoo.
0..7‐Asasumof: