Specifications
PART 2 – Cellular SocketModems Chapter 6 – SocketModem iCell EV-DO
Multi-Tech Systems, Inc. Universal Socket Hardware Guide for Developers (S000342P) 104
Power Measurements
Power Draw* for the MTSMC-EV2-MI-IP
Input Voltage = 5.0
Volts
Sleep
Mode
Typical
Maximum
1
Peak Tx
2
In-Rush
Current
3
CDMA 2000
800mhz
Current (AMPS)
0.044
0.230
0.785
1.020
Watts
0.22 1.14 3.84
CDMA 2000
1900mhz
Current (AMPS)
0.044
0.245
0.835
1.10
Watts
0.218 1.21 4.08
In-Rush Current (AMPS) at Reset or power on. (Approx. 3ms duration) 1.71
Power Draw* for the MTSMC-EV2-IP
Input Voltage = 5.0
Volts
Sleep
Mode
Typical
Maximum
1
Peak Tx
2
In-Rush
Current
3
CDMA 2000
800mhz
Current (AMPS)
0.044
0.225
0.770
1.000
Watts
0.22 1.11 3.77
CDMA 2000
1900mhz
Current (AMPS)
0.044
0.245
0.830
1.10
Watts
0.218 1.21 4.06
In-Rush Current (AMPS) at Reset or power on. (Approx. 3ms duration) 1.75