HYLAFAX-CONFIG(5F) HYLAFAX-CONFIG(5F)
Class2PWCmd string AT+FPW Class 2: set password string
Class2RecvDataTrigger string ‘‘\21’’ Class 2: character to send to trigger recv
Class2RELCmd string −Class 2: command to enable byte-aligned EOL codes
Class2SACmd string AT+FSA Class 2: set destination subaddress string
Class2SendRTC boolean No Class 2: append RTC to page data on transmit
Class2SFLOCmd string −Class 2: command to set software flowcontrol
Class2SPLCmd string AT+FSPL Class 2: command to set polling request
Class2TBCCmd string AT+FTBC=0 Class 2: command to enable stream mode
Class2UseLineCount boolean No Class 2: use the line count from the firmware decoder
Class2UseHexboolean No Class 2: parse capabilities strings as hexvalues
Class2XmitWaitForXON boolean Yes Class 2: wait for XON before sending facsimile data
Class2Cmd string AT+FCLASS=2.0 Class 2.0: command to enter class 2/2.0
Class2AbortCmd string AT+FKS Class 2.0: command to abort active session
Class2APCmd string AT+FAP Class 2.0: enable support for sending and receiving SUB, SEP,a
Class2APQueryCmd string AT+FAP=? Class 2.0: query capabilities for sending and receiving SUB, SEP
Class2BORCmd string AT+FBO=0 Class 2.0: command to setup bit order
Class2BUGCmd string AT+FBU=1 Class 2.0: command to enable HDLC frame tracing
Class2CIGCmd string AT+FPI Class 2.0: command to set polling identifier
Class2CRCmd string AT+FCR=1 Class 2.0: command to enable receive capability
Class2CQCmd string −Class 2.0: command to setup copyquality parameters
Class2CQQueryCmd string AT+FCQ=? Class 2.0: command to query modem copyquality capabilities
Class2DCCCmd string AT+FCC Class 2.0: command to set modem capabilities
Class2DCCQueryCmd string AT+FCC=? Class 2.0: command to query modem capabilities
Class2DisableV17Cmd string −Class 2.0: command to disable V.17 support
Class2DISCmd string AT+FIS Class 2.0: command to set session parameters
Class2ECMType string ‘‘2.0’’ Class 2.0: ECM specification type to follow
Class2HexNSF boolean Yes Class 2.0: parse NSF strings as hexvalues
Class2HFLOCmd string AT+FLO=2 Class 2.0: command to set hardware flowcontrol
Class2JPEGSupport boolean No Class 2.0: use modem JPEG support
Class2LIDCmd string AT+FLI Class 2.0: command to set local identifier string
Class2MINSPCmd string AT+FMS Class 2.0: command to set minimum transmit speed
Class2NFLOCmd string AT+FLO=0 Class 2.0: command to set no flowcontrol
Class2NRCmd string AT+FNR=1,1,1,1 Class 2.0: command to set negotiation message reporting
Class2PACmd string AT+FPA Class 2.0: set polling address string
Class2PHCTOCmd string AT+FCT=30 Class 2.0: command to set Phase C timeout parameter
Class2PIECmd string AT+FIE=0 Class 2.0: command to set procedure interrupt handling
Class2PWCmd string AT+FPW Class 2.0: set password string
Class2PTSCmd string AT+FPS Class 2.0: command to set receivedpage status
Class2PTSQueryCmd string AT+FPS? Class 2.0: command to query receivedpage status
Class2RecvDataTrigger string ‘‘\22’’ Class 2.0: character to send to trigger recv
Class2RELCmd string −Class 2.0: command to enable byte-aligned EOL codes
Class2RTFCC boolean No Class 2.0: enable real-time fax compression conversion
Class2SACmd string AT+FSA Class 2.0: set destination subaddress string
Class2SendRTC boolean No Class 2.0: append RTC to page data on transmit
Class2SFLOCmd string AT+FLO=1 Class 2.0: command to set software flowcontrol
Class2SPLCmd string AT+FSP Class 2.0: command to set polling request
Class2TBCCmd string AT+FPP=0 Class 2.0: command to enable stream mode
Class2UseLineCount boolean No Class 2.0: use the line count from the firmware decoder
Class2UseHexboolean No Class 2.0: parse capabilities strings as hexvalues
PagerSetupCmds string −commands for setting up modem for a pager call
PagerMaxMsgLength integer 128 max length of a text message
IXOService string ‘‘PG’’ IXO: service identification string
IXODeviceID string ‘‘1’’ IXO: device identification string
$Date$ 6