HYLAFAX-CONFIG(5F) HYLAFAX-CONFIG(5F)
Class1GreyJPEGSupport boolean No Class 1/1.0: to enable greyJPEG fax support
Class1HookSensitivity integer 0 Class 1/1.0: times to ignore on-hook detection
Class1JBIGSupport string see below Class 1/1.0: to enable monochrome JBIG fax support
Class1MRSupport boolean Yes Class 1/1.0: enable 2-D MR support
Class1MMRSupport boolean Yes Class 1/1.0: enable 2-D MMR support
Class1NFLOCmd string −Class 1/1.0: command to set no flowcontrol
Class1PageLengthSupport integer 7 Class 1/1.0: coded value for modem page length support
Class1PageWidthSupport integer 7 Class 1/1.0: coded value for modem page width support
Class1RecvAbortOK integer 200 Class 1/1.0: max wait (ms) for ‘OK’’ after recv abort
Class1RecvIdentTimer integer 40000 Class 1/1.0: max wait (ms) for initial ident frame
Class1RMPersistence integer 2 Class 1/1.0: times to attempt high-speed carrier recv
Class1SFLOCmd string −Class 1/1.0: command to set software flowcontrol
Class1PPMWaitCmd string AT+FTS=7 Class 1/1.0: command to stop and wait before PPM
Class1ResponseWaitCmd string −Class 1/1.0: command to wait before TCF response
Class1Resolutions integer 0x7F Class 1/1.0: bitmap of supported resolutions
Class1RMQueryCmd string AT+FRM=? Class 1/1.0: command to query modem data reception rates
Class1TCFWaitCmd string AT+FTS=7 Class 1/1.0: command to stop and wait before TCF
Class1TMQueryCmd string AT+FTM=? Class 1/1.0: command to query modem data transmission rates
Class1EOPWaitCmd string AT+FTS=9 Class 1/1.0: command to stop and wait before EOP
Class1ModemHasDLEBug boolean No Class 1/1.0: modem fails to double DLE in V.21
Class1MsgRecvHackCmd string "" Class 1/1.0: command to avoid +FCERROR before image data
Class1TCFRecvHackCmd string "" Class 1/1.0: command to avoid +FCERROR before TCF
Class1TCFMaxNonZero integer 10 Class 1/1.0: max% of non-zero data in good TCF
Class1TCFMinRun integer 1000 Class 1/1.0: minimum zero run in good TCF
Class1TCFMinRunECMMod integer 2 Class 1/1.0: modify minimum zero run in ECM by this factor
Class1TCFRecvTimeout integer 4500 Class 1/1.0: max wait (ms) for TCF
Class1TMConnectDelay integer 0 Class 1/1.0: delay between +FTM CONNECT and data transmission
Class1SwitchingCmd string AT+FRS=7 Class 1/1.0: command to ensure silence after HDLC reception
Class1ValidateV21Frames boolean No Class 1/1.0: check FCS against receivedframes
Class2Cmd string AT+FCLASS=2 Class 2: command to enter class 2/2.0
Class2AbortCmd string AT+FK Class 2: command to abort active session
Class2APCmd string AT+FAP Class 2: enable support for sending and receiving SUB, SEP,a
Class2APQueryCmd string AT+FAP=? Class 2: query capabilities for sending and receiving SUB, SEP
Class2BORCmd string AT+FBOR=0 Class 2: command to setup bit order
Class2BUGCmd string AT+FBUG=1 Class 2: command to enable HDLC frame tracing
Class2CIGCmd string AT+FCIG Class 2: command to set polling identifier
Class2CRCmd string AT+FCR=1 Class 2: command to enable receive capability
Class2CQCmd string −Class 2: command to setup copyquality parameters
Class2CQQueryCmd string AT+FCQ=? Class 2: command to query modem copyquality capabilities
Class2DCCCmd string AT+FDCC Class 2: command to set modem capabilities
Class2DCCQueryCmd string AT+FDCC=? Class 2: command to query modem capabilities
Class2DisableV17Cmd string −Class 2: command to disable V.17 support
Class2DISCmd string AT+FDIS Class 2: command to set session parameters
Class2DDISCmd string −Class 2: command to set session parameters before dialing
Class2ECMType string ‘‘2’ Class 2: ECM specification type to follow
Class2HexNSF boolean Yes Class 2: parse NSF strings as hexvalues
Class2HFLOCmd string −Class 2: command to set hardware flowcontrol
Class2JPEGSupport boolean No Class 2: use modem JPEG support
Class2LIDCmd string AT+FLID Class 2: command to set local identifier string
Class2MINSPCmd string AT+FMINSP Class 2: command to set minimum transmit speed
Class2NFLOCmd string −Class 2: command to set no flowcontrol
Class2PACmd string AT+FPA Class 2: set polling address string
Class2PHCTOCmd string AT+FPHCTO=30 Class 2: command to set Phase C timeout parameter
Class2PTSCmd string AT+FPTS Class 2: command to set receivedpage status