Specifications
HYLAFAX-CONFIG(5F) HYLAFAX-CONFIG(5F)
DistinctiveRings string −configuration for distinctive ring cadences
DRingOffstring − distinctive ring ‘‘off’’cadence indicator
DRingOn string −distinctive ring ‘‘on’’cadence indicator
DynamicConfig string −script for dynamic receive configuration
EGettyArgs string −arguments passed to external getty program
FAXNumber string −facsimile modem phone number
FaxRcvdCmd string bin/faxrcvd notification script for receivedfacsimile
GettyArgs string −arguments passed to getty program
Include² string −include another file
InternationalPrefix² string −dialing prefix for international calls
JobControlCmd¹ string −job control command
JobReqBusy integer 180 requeue interval for BUSY dial result
JobReqDataConn integer 300 requeue interval for data connection dial result
JobReqNoAnswer integer 300 requeue interval for NO ANSWER dial result
JobReqNoCarrier integer 300 requeue interval for NO CARRIER dial result
JobReqNoFCon integer 300 requeue interval for carrier without +FCON dial result
JobReqOther² integer 300 requeue interval for ‘‘other’’problems
JobReqProto integer 60 requeue interval after fax protocol error
JobRetryBusy integer − number of retries for BUSY dial result
JobRetryDataConn integer − number of retries for data connection dial result
JobRetryNoAnswer integer − number of retries for NO ANSWER dial result
JobRetryNoCarrier integer 1 number of retries for NO CARRIER dial result
JobRetryOther integer − number of retries for ‘‘other’’problems
LockDataCalls boolean Yes lock modem for the duration of an inbound data call
LockVoiceCalls boolean Yes lock modem for the duration of an inbound voice call
LogCalls boolean Yes Log all incoming calls as CALL records in xferfaxlog
LogFacility² string daemon syslog facility name for ServerTracing messages
LogFileMode octal 0600 protection mode to use for session log files
LocalIdentifier string −local station identification string
LongDistancePrefix string −dialing prefix for long distance calls
MaxBatchJobs¹ integer 64 max jobs in a batch
MaxConcurrentCalls¹ integer 1 max concurrent jobs to process for a destination
MaxConsecutiveBadLines integer 5 max consecutive bad rows for OK page quality
MaxDials¹ integer 12 max phone calls to maketotransmit a job
MaxRecvPages integer unlimited max pages to permit in a receive
MaxSendPages¹ integer unlimited max pages to permit in a send
MaxSetupAttempts integer 2 max attempts to initialize a modem
MaxTries¹ integer 3 max attempts to transmit a job
MinAcceptedLineCount integer 10 min number of rows for OK page quality
ModemGroup¹ string −define a name for a set of modems
ModemPriority integer 255 scheduling priority for outbound jobs
ModemReadyState string R ‘‘ready state’’sent by faxgetty
ModemRingResponse string −command to respond after hearing RING
ModemRingsBeforeResponse integer 0 the number of rings before ModemRingResponse
NoAnswerVoice boolean false disable the answering of voice-indicated calls
NoCarrierRetrys integer − Deprecated - See JobRetryNoCarrier
NotifyCmd¹ string bin/notify user notification command script
PageChop¹ string last control automatic truncation of trailing whitespace
PageChopThreshold¹ float 3.0 whitespace truncation threshold (inches)
PCL2FaxCmd¹ string bin/pcl2fax PCL RIP command script
PercentGoodLines integer 95 percentage of good rows for OK page quality
PollLockPokeModem boolean false check on modem every time the lock is polled
PollLockWait² integer 30 polling interval for lockfile presence/removal(secs)
PollModemWait integer 30 polling interval when in ‘‘modem wait’’state (secs)
$Date$ 2