Owner`s manual

MT5634ZPW-PCI
41
3 AT Commands, S-Registers and Result Codes
Command: O Return Online to Data Mode
Values: 0, 1, 3
Default: None
Description: O0 Exit online command mode and return to data mode.
O1 Issue a retrain and return to online data mode.
O3 Issue a rate renegotiation and return to data mode.
Command: Q
n
Result Codes Enable/Disable
Values:
n
= 0 or 1
Default: 0
Description: Q0 Enable result codes.
Q1 Disable result codes.
Command: S
r
=
n
Set Register Value
Values:
r
= S-register number;
n
varies
Default: None
Description: Set value of register S
r
to value of
n
, where
n
is
entered in decimal format.
Command: S
r
? Read Register Value
Values:
r
= S-register number
Default: None
Description: Read value of register
S
r
and display value in 3-digit
decimal form.
Command: V
n
Result Code Format
Values:
n
= 0 or 1
Default: 1
Description: V0 Displays result codes as digits (terse response).
V1 Displays result codes as words (verbose response).