User guide
MT5634ZPX Quick Start Guide
7
2. Remove the cover from the computer as instructed in the computer manual.
3. Select an empty ISA expansion slot. Remove the expansion slot cover and
save the retaining screw.
4. Place the MultiModem directly above the expansion slot and gently, but firmly,
push it into the connector until the card’s retaining bracket is flush against the
computer chassis.
5. Fasten the retaining bracket to the computer chassis with the screw saved in
step 3.
6. Replace the cover of the computer.
Step 4 - Run Add Hardware Wizard
1. Click on Start I Control Panel I Add Hardware and the Add Hardware Wizard
screen is displayed.
2. Click on the Next button on the Add Hardware Wizard screen. The wizard will
pause a few seconds trying to detect the new device. Windows will not detect
any device, if the system does, it may be some other device that has not been
properly installed.
3. When Is the hardware connected? screen displayed, click on Yes, I have
already connected the hardware option and click Next.
4. The following hardware is already installed on your computer screen is
displayed. Scroll down to Add a new hardware device and highlight. Click
Next.
5. Click on Install the hardware that I manually select from a list [Advanced]
and click Next.
6. From the following list below, select the type of hardware you are
installing screen is displayed. Scroll down to Ports [COM & LPT] option.
Click Next.
7. Select the device driver you want to install for this hardware. In the Model
window, select Communications Port and click Next.
8. When the Completing the Add Hardware Wizard screen appears, click on
View or change resources for this hardware [Advance] option and the Add
Hardware Wizard Properties screen appears, click on Set Configuration
Manually option and ckick OK.
9. The Add Hardware Wizard Properties window for Communications Port
[COM3] is displayed. In the Setting based on: window, chose the basic
configuration that mostly matches your situation. For example Basic
configuration 0003 has an I/O range 02F8-02FF used by: Communications
Port [COM2].
10. To change either of the settings, click on either I/O Range or IRQ in the
Resource type window and then click on Change Setting button.
11. If you need to change the IRQ, the Edit Interrupt Request window is
displayed. In the Value: window click on either the up arrow or the down arrow
to choose your interrupt value that you recorded in Step 5. Click OK.