Technical information

Frequently Asked Questions (FAQs)
16
ISDN PRI (MTPRI-HD23B and MTPRI-HD30B) FAQs
Q23. What switch types does the CommPlete support?
A23. DMS-100, 5ESS, NI-2, NTT, 1TR6, EuroISDN (NET 5), VN2 and VN3, Japan
NTT.
Q24. Can I allow users to place an analog modem call and/or an
ISDN call to the unit?
A24. Yes. Arrange to have a single line and your users can dial in with either analog
modems or ISDN T/As. The unit will automatically detect and handle each call as
required.
Q25. Do I have to set SPID and directory numbers for each B-
Channel, similar to the way the BRI products work?
A25. No, SPID and Directory numbers are not required, since the single D-channel
handles all the call setup and teardown into the telco network.
Q26. When I order a PRI line from the telco, can I order a PRI line
without T1 ?
A26. No, you must order a T1 line with PRI signaling. PRI signaling is an additional
charge to the T1. On the other hand, when you order a PRI line, the monthly
charge for the PRI line doesn't include the T1. So, be sure to ask your telco
representative about these options.
Q27. What ordering information do I need?
A27. Ordering a circuit for PRI is basically the same as for a T1. Specify Extended
Super Frame (ESF) and B8ZS, then terminate at the de-mark with a “smart jack”.
If you'll be dialing in and out, then you will need to tell your telco that it's a “two-
way” circuit, and that you need 23 B-channels and one D-channel.