Specifications

135
MANAGING TASKS & DATA • DATA BROWSER
TECHNICAL SUPPORT 978-486-0086 • support@burk.com • www.burk.com
Condition gives the alarm threshold for the channel, displaying
the preset condition for an alarm and current condition. A meter
condition might show 5.2V > 5 meaning that the preset condition
for the meter channel is 5 and the current condition is 5.2 thus
triggering an alarm. A status condition might show XMTR OFF
signifying that if the transmitter is off an alarm is triggered.
Message displays the textual description of the alarm.
Note opens a note window allowing you to document alarms,
conditions, and actions taken.
To Delete a Time Stamp
1. In the make selection pane, select the unit that has a time
stamp to be deleted.
2. Select the time stamp to be deleted. The complete row needs
to be selected.
3. Right-click on the unit and then click Delete Site or Unit Data.
Advanced users can open
their site's database with
Microsoft Access® which
provides them with a much wider
range of database capabilities than
those provided with the Data
Browser. Customized queries,
sorting, storage, and reporting are
some of these capabilities. Burk
Technology is not able to provide
any technical assistance to users
wishing to explore these enhanced
features. All modifications to the
database are done by the user with
the understanding that any and/or
all data may be lost by doing this.
There is no possible way to
reconstruct damaged or destroyed
data when done outside of the
VRC2500 software.
!