Power
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into your power source when
determining product load.
Power draw for MT200A2W-G
Input Voltage= 9.0Volts
Sleep Mode
Typical
Maximum
Peak Tx
Peak Rst (Inrush)
GSM850
9.26
9.25
9.24
Current(AMPS)
0.111
0.172
0.254
1.43
Watts
1.03
1.59
2.35
Inrush Current (AMPS) (approx. 8ms duration)
1.20
Input Voltage= 16.0 Volts
Sleep Mode
Typical
Maximum
Peak Tx
Peak Rst (Inrush)
GSM850
16.00
16.00
16.00
Current(AMPS)
0.068
0.105
0.151
0.745
Watts
1.09
1.68
2.42
Inrush Current (AMPS) (approx. 8ms duration)
1.56
Power Draw for the MT200A2W-H5 (GSM850/HSDPA)
GSM850
Input Voltage =9V
Sleep Mode
Idle
Typical
Peak Tx
Peak Rst (Inrush)
Current (A)
0
0.125
0.234
1.51
2.560
Watts
0
1.13
2.11
Input Voltage =16V
Sleep Mode
Idle
Typical
Peak Tx
Peak Rst (Inrush)
Current (A)
0
0.074
0.137
0.715
2.120
Watts
0
1.18
2.19
HSDPA
Input Voltage =9V
Sleep Mode
Idle
Typical
Peak Tx
Peak Rst (Inrush)
Current (A)
0
0.129
0.261
0.34
2.560
Watts
0
1.16
2.35
Input Voltage =16V
Sleep Mode
Idle
Typical
Peak Tx
Peak Rst (Inrush)
Current (A)
0
0.074
0.137
0.440
2.120
Watts
0
1.18
2.19
Notes for models G2 and H5
● Peak Tx: The peak current during maximum data transmission.
● Typical: The average current during maximum data transmission.