System information
6. Enter a name for the new profile in the field Profile Name.
7. Click on Save to save the new profile.
Figure 127. Alert Manager - Edit Profiles by Profile Composition
3.2.3 Severity
The severity code classifies the importance of an alert. The range is from 0
(Failure) to 7 (Information). The lower the importance of an error the higher the
severity code value. That means a severity code of 0 is very important and
immediate action should be taken as response to the alert. The severity code 7
is used for information and no action has to be taken.
The severity code is one of the alert attributes used to classify and filter alert
messages. This attribute is also used to define forwarding profiles.
3.2.4 Alert Actions
The following actions can be defined for alert forwarding in the Alert Editor
window of the Alert Manager:
•
Send alert to alphanumeric pager through TAP using a modem
Forward the alarm to a alphanumeric pager through the Telephone
Application Program (TAP). Define the COM Port (P1) where the modem is
connected and enter the pager′s ID (P3), the TAP access number (P2) and
additional text (P4) to be sent to the pager.
•
Activate a numeric pager using a modem
Forward the alarm to a numeric pager. Define the COM port where the
modem is connected and enter the pager′s telephone number.
•
Notify user with pop-up