Specifications

48
MT1932ZDX Quick Reference Guide
S-Registers
Certain modem values, or parameters, are stored in memory locations
called S-registers. Use the S command to read or to alter the contents of
S-registers (see previous section).
Register Unit Range Default Description
S0
1 ring 0, 1–255 1 Sets the number of rings until
the modem answers.
ATS0=0
disables auto-answer
completely.
S1
1 ring 0–255 0 Counts the rings that have
occurred.
S2
decimal 0–127 43 (+) Sets ASCII code for the
escape code character.
S3
decimal 0–127 13 (^M) Sets ASCII code for the
RETURN character.
S4
decimal 0–127 10 (^J) Sets ASCII code for the LINE
FEED character.
S5
decimal 0–127 8 (^H) Sets ASCII code for the
BACKSPACE character.
S6
1 sec. 2–255 2 Sets the time the modem
4–255† 4† will wait for a dial tone
4–7‡ 4‡ before aborting a call.
S7
1 sec. 1–255 45 Sets the time the modem
1–45* 45* will wait for a carrier signal
1–55‡ 55‡ before aborting a call.
S8
1 sec. 0–255 2 Sets the length of a pause
4–255† 4† caused by a comma charac-
4–7‡ 4‡ ter in a dialing command.