User guide

75
Chapter 5 - Commands
conditions that affect the link's operation, such as
the downline load, modem type, flush timer value
and the response time setting.
Local MultiMux Composite Settings
INIATE DOWN MODEM FLUSH RESPONSE
LINE LOAD TYPE TIMER TIME
OFF INTERNAL 10ms 3
#RB Status Report Baud Rate
This command sets the baud rate of the status
report generated by the #S0 command on the
system supervisor console display. The speed
options are as follows:
#RB300 : 300 bps #RB120O : 1200 bps
#RB2400 : 2400 bps #RB4800 : 4800 bps
#RB9600 : 9600 bps #RB19200 : 19200bps
#RT0-99 Status Report Time
This command sets the time interval in hours at
which the status report generated by the #S0
command is displayed on thesystem supervisor
console display. The intervals are in hour increments
from 1 to 99 hours with #RT0 being the off condition.
$Muxl Inactivity Timer
The inactivity timer allows the mux to drop DTR
which causes the modem to hang up when no
characters are received on any channel for the
specified time. The timer is enabled with the$Muxl
command where the xx is the desired inactivity time
in minutes (00-99 minutes). When a character is
received on a channel, the mux raises the DTR
signal allowing the modem to dial. When the xx is
00, the timer if off. The default for the inactivity timer
is off.