Chapter 5 - Commands
10 msec and #FT1 sets the flush time value to 20
msec. The default is #FT0.
$L List Composite Link Configuration
The List Composite Link Configuration command
causes the MultiMux to display its internal composite
link parameters on the supervisory console. Five
different parameter displays can be shown
depending on the internal composite link device. The
first example shows the default parameters for a
9600 bps internal modem. Example two shows the
14.4K bps internal modem. The third example shows
two sets of parameters for an internal the MMH2834
internal modem. The fourth example shows the
MultiMux configured for a 19.2K bps external
composite link modem (8-position DIP switch SW2
in the down position). Example five shows the
MultiMux configured for an internal composite link
DSU.
MODEM TXMIT RECV CABLE LINK LINK T/2 ECHO TEST
CONFIGURE LEVEL LEVEL EQU AMP DELAY EQU PROT MODE
V29/9600 -0DB -43DB 0.0KM OFF OFF T2 OFF OFF
MODEM TXMIT RECV CABLE LINK LINK T/2 ECHO TEST
CONFIGURE LEVEL LEVEL EQU AMP DELAY EQU PROT MODE
V33/14400 -0DB -43DB 0.0KM OFF OFF T2 OFF OFF
LINK LINK MUX MUX BACK TO EOF XMT EOF RCV LOOP
DEVICE FORMAT SPEED CLOCKING BACK CHARACTER CHARACTER BACK
MMH2834 SYNC 57600 EXTERNAL OFF FF FF OFF
TRANSMISSION SYNC DIAL 2 OR 4 ANSWER TRANSMIT COMMAND
RATE ASYNC LEASED WIRE ORIGINATE LEVEL MODE
28800 SYNC LEASED 4 WIRE ANSWER 0 DB ON
LINK LINK MUX MUX BACK TO EOF XMT EOF RCV LOOP
DEVICE FORMAT SPEED CLOCKING BACK CHARACTER CHARACTER BACK
External SYNC 19200 EXTERNAL OFF FF FF OFF
LINK LINK DSU DSU EOF XMT EOF RCV LOOP
DEVICE FORMAT SPEED CLOCKING CHARACTER CHARACTER BACK
DSU SYNC 56000 DSU N/A N/A OFF
#L List Composite Link Settings
This command lists the status of the link
configuration parameters. The display indicates the