Specifications
sigmadue - IEC 61131-3 Function Block Library
82
2-3-19 bAO08DP
FB Prototype
bAO08DP
Input parameters
Output parameters
Description
This Function Block sets the output value for all the channels of the module using
±100% range value. As inputs the FB wants the network connection, the node
identifier and the value of the output. Please note that this module is able to gener-
ate only signals in the range ±10V.
Label Type Description
Network DWORD CAN Network Connection
NodeID USINT CANopen Device Identifier
Ch1 REAL Input1 in [± 100%]
Ch2 REAL Input2 in [± 100%]
Ch3 REAL Input3 in [± 100%]
Ch4 REAL Input4 in [± 100%]
Ch5 REAL Input5 in [± 100%]
Ch6 REAL Input6 in [± 100%]
Ch7 REAL Input7 in [± 100%]
Ch8 REAL Input8 in [± 100%]
Label Type Description
Confirm BOOL Function Block Confirm
NETWORK
NODEID
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
DWORD
USINT
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
¡
¡
¡
¡
¡
¡
¡
¡
¡
¡
BOOL CONFIRM
¡