Specifications

ISI3334/4 Hardware/Driver Installation Manual
34
S25
DTR Dropout Time
Unit: 100 mSec.
Range: 0, 1 through 255
Default: 0
Description: Defines DTR dropout time. 0 default equals
50ms.
S30
Inactivity Timer
Unit: 1 minute
Range: 0-255
Default: 0
Description: Inactivity timer used to disconnect the
modem.
S32
Time Elapse for Escape Sequence
Unit: 1 second
Range: 0-255
Default: 20
Description: Sets the duration in which modem waits for
a <CR> to be entered during escape
sequence execution.
S34
Buffer Length of Command Mode...After On-line Escape Sequence
Unit: ASCII Character
Range: 0-60
Default: 10
Description: Sets buffer length of command mode after
on-line escape sequence.
S36
Time Between DTR Inactive and Modem Off-Hook
Unit: 1 Second
Range: 0-255 seconds
Default: 0
Description: Sets the time between DTR inactive (low)
and the modem going
off-hook
. The DTR
Busy-out feature is disabled with S36=0.