Specifications

ISI3334/4 Hardware/Driver Installation Manual
16
COMMAND: %DP
n
VALUES: n = 0 or 1
DEFAULT: %DP0
DESCRIPTION:
%DP0 selects not to read Line Probe
Information from DSP during handshaking.
%DP1 selects read Line Probe Information
from DSP during handshaking.
COMMAND: E
n
VALUES: n = 0 or 1
DEFAULT: E1
DESCRIPTION:
E0 selects do not echo Command mode
characters.
E1 selects echo Command mode
characters.
COMMAND: $EB
n
VALUES: n = 0 or 1
DEFAULT: $EB0
DESCRIPTION:
$EB0 selects 10 bit mode.
$EB1 selects 11 bit mode.
COMMAND: &E
n
VALUES: n = 0 thru 15
DEFAULT: &E1, &E4, &E6, &E10, &E13, &E15
DESCRIPTION:
&E0 selects no error correction.
&E1 selects V.42 Auto-reliable Mode.
&E2 selects V.42 Reliable Mode.
&E3 selects no modem-initiated flow control.
&E4 selects CTS modem-initiated flow
control.
&E5 selects Xon/Xoff modem-initiated flow
control.
&E6 selects Xon/Xoff not passed through.
&E7 selects Xon/Xoff passed through.
&E8 selects Enq/Ack pacing off.
&E9 selects Enq/Ack pacing on.
&E10 selects Normal Mode flow control off.