Appendix D - Disabling the Internal DSU
Perform the following procedure if your WAN network has been upgraded to T1/E1 and you now want
to
disable
the MultiFRAD’s internal DSU and use the back panel Trunk connection to obtain data
rates of up to 2.048 Mbps.
1 Turn off the MultiFRAD using the back panel Power switch.
2 Locate the access window (side slot opening) near the left front corner of the MultiFRAD.
3 Using a small flat blade screwdriver or similar tool, press
down
on DIP Switch 2
(Figure D-1) until it is even with all the other DIP switches; the internal DSU is now disabled.
OPEN
12345678
DIP switch 2 UP; internal DSU is enabled.
DIP switch 2 DOWN; internal DSU is disabled.
OPEN
12345678
Figure D-1. DIP Switch 2 Location and Functions
4 If your trunk connection is V.35 rather than the default RS232C, refer to V.35 Shunt
Procedure in Chapter 2 - Installation and move the Trunk shunt to the V.35 socket.
5 Disconnect the RJ-45 cable from the DSU jack and connect a trunk cable (Appendix A) to the
DB25 female TRUNK connector on the back panel of the MultiFRAD.
6 Reapply power to the MultiFRAD, then configure the Trunk port as the WAN connection.