Specifications
MT100UCC-C2 MODEL OVERVIEW
Power Draw MT100UCC-C2
5 volts Cellular call box Average Peak TX Total inrush Total inrush
connection no measured current amplitude charge measured charge duration
data (amps) (amps) at current (amps) in MilliCoulombs during power up
maximum power (mC) (uS)
US Cellular 800 0.066 0.516 0.568 0.36 193
Mhz
US PCS 1900 Mhz 0.066 0.686 0.748 0.36 193
Note: Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source when
determining product load.
Peak Tx: The peak current during a CDMA connection transmitting data at max power.
Maximum Power: The continuous current during maximum data rate with the radio transmitter at maximum
power.
Inrush Charge: The total inrush charge at power on.
Pinout Specifications
Pins Signal Name Logic Level Voltage I/O Description
JP2-1 VCC 5.0 PWR DC input power
JP2-2 USB DN 3.3 I/O USB data
JP2-3 USB DP 3.3 I/O USB data
JP2-4 GND GND GND Ground
22 QuickCarrierâ„¢ USB-E MT100UCC-C2 Developer Guide