Specifications
MT100UCC-C2 MODEL OVERVIEW
Category Description
Operating
Supply range: 4.75 V to 5.25 V
Voltage
1.1A nominal current
Device may be damaged if voltage exceeds 5.5 V
Input Power
USB bus powered
SMS
Point-to-Point messaging
Mobile-Terminated SMS
Mobile-Originated SMS
Certifications, Compliance, Warranty
EMC
FCC Part 15 Class B
Compliance
Radio
FCC Part 22
Compliance
FCC Part 24
Safety
UL 60950-1 2nd edition
Compliance
cUL 60950-1 2nd edition
IEC 60950-1 2nd edition
Network
Verizon
Compliance
Sprint
Aeris
Warranty
2 years
Note: The radio's performance may be affected at the temperature extremes. This is considered normal. The radio
is designed to automatically fallback in class and reduces transmitter power to avoid damage to the radio. There is
no single cause for this function. Rather, it is the result of an interaction of several factors, such as the ambient
temperature, the operating mode and the transmit power.
You may need to reduce the temperature range if airflow is limited around the cellular radio. Test and verify the
temperature range if the QuickCarrier USB-E is designed into an enclosed chassis.
20 QuickCarrierâ„¢ USB-E MT100UCC-C2 Developer Guide