User guide

CUSTOM AT COMMANDS
115 AT Commands for EV-DO-EV3 Modems
Syntax
Command Command type
AT#ACAL=[<mode>] Set
AT#ACAL? Read
AT#ACAL=? Test
Parameters and Values
<mode>
0 Disables the automatic call function. Default: 0.
1 Enables the automatic call function. If enabled (and &D2 is issued), the transition
OFF/ON of DTR causes an automatic call to the first number (position 0) stored in
the internal phonebook.
Notes
Type of call depends on the last issue of command +FCLASS.
See &Z to write and &N to read the number on module internal phonebook.
Extended Automatic Call #ACALEXT
Set command enables or disables the extended automatic call function.
Read command reports either whether the automatic call function is currently enabled or not, and the last
<index> setting in the format:
#ACALEXT: <mode>,<index>
Test command returns the available values range for <mode> and <index>.
Syntax
Command Command type
AT#ACALEXT=<mode>,<index> Set
AT#ACALEXT? Read
AT#ACALEXT=? Test
Parameters and Values
<mode>
0 Disables the automatic call function. Default: 0.
1 Enables the automatic call function from internal phonebook.
<index> Indicates a position in the currently selected phonebook.
If the extended automatic call function is enabled and &D2 is issued, the
transition OFF/ON of DTR causes an automatic call to the number stored in
position <index> in the selected phonebook.
Notes
Type of call depends on the last issue of command +FCLASS
Issuing #ACALEXT causes the #ACAL <mode> to be changed.
Issuing AT#ACAL=1 causes the #ACALEXT <index> to be set to default.
It is recommended to NOT use contemporaneously with either #ACALEXT and #ACAL
See &Z to write and &N to read the number on module internal phonebook.