User guide

CUSTOM AT COMMANDS
109 AT Commands for EV-DO-EV3 Modems
#E2SMSRI: 0
OK
AT#E2SMSRI=50
OK
AT#E2SMSRI?
#E2SMSRI: 50
OK
Read Analog/Digital Converter Input #ADC
Execution command reads pin <adc> voltage, converted by ADC and outputs in the format:
#ADC: <value>
where:
<value> - pin<adc> voltage, expressed in mV
Read command reports the pins voltage, converted by ADC, in the format:
#ADC: <value>[<CR><LF>#ADC: <value>[…]]
Test command reports the supported values of <adc>, <mode>, and <dir> command parameters.
Syntax
Command Command type
AT#ADC=[<adc>,<mode>[,dir]] Execute
AT#ADC? Read
AT#ADC=? Test
Parameters and Values
<adc> Pin index
1 Available for EV3 and C2.
<mode> Required action.
2 Query ADV value.
<dir> Direction. Interpretation not currently implemented.
0 No effect.
Note:
Command returns the last valid measure.