CC9600 Chassis User Guide
CC9600 Chassis User Guide P/N 82064902, Revision C Copyright © 1997 by Multi-Tech Systems, Inc. All rights reserved. This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc.
Federal Communications Commission Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
No repairs are to be made by you. Repairs are to be made only by MultiTech Systems or its licensees. Unauthorized repairs void registration and warranty. Manufacturer: MultiTech Systems, Inc. Trade Name: CommPlete Model Number: CC9600 FCC Registration Number: AU7USA-31090-DE-E Facility Interface Code: Service Order Code: 04DU9-ISN, 04DU9-BN 6.0N Modular Jack (USOC): RJ48C Service Center in USA: MultiTech Systems, Inc.
Canadian Limitations Notice Notice: The ringer equivalence number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination of a interface may consist of any combination of devices subject only to the requirement that the sum of the ringer equivalence numbers of all the devices does not exceed 5. Notice: The Industry Canada label identifies certificated equipment.
• The power supply cords are intended to serve as the disconnect devices. The outlet sockets must be installed near the equipment and be easily accessible. • To reduce the risk of shock, all openings should be covered during normal operation of the equipment. • Both power cords must be removed to remove all power from the chassis. The power supplies are connected in parallel, so that both power supplies supply power to all power busses in the chassis.
Vigtige Sikkerhedskrav • Det er ikke nødvendigt at foretage manuelle justeringer af udstyret, for at tilslutte udstyret til elektrisitetsuettet indenfor de navute spændingsfrekvensgreuser. • Strømforsyningsledningen er beregnet til at fungere som afbryder. Stikkontakten skal installeres nær ved udstyret og skal være let tilgængelig. • Nedsæt risikoen for stød, ved at tildække alle udstyrets åbninger under normal drift.
viii CommPlete Communications Server
Table of Contents 1 Introduction Introduction ...................................................................................................................................................... 2 Key Features ...................................................................................................................................................... 2 Manual Organization................................................................................................................................
x CommPlete Communications Server
1 Introduction CommPlete Communications Server 1
CC9600 Chassis User Guide Introduction The CC9600 chassis is the housing for the CommPlete Communications Server. It can contain one chassis controller module, two power supply modules (one is required, and two are recommended), four independent RASCard servers, and 96 modems (12 modem cards, with eight modems per card) or four PRI cards.
1 Introduction Technical Specifications Model Number CC9600 Number of Slots 16 Number of Fans 6 External Connectors Two AC power receptacles Environmental Temperature range: 0°–40° C (32°–104° F) Humidity range: 0–95% (noncondensing) Dimensions 31.1 × 48.3 × 36.8 cm (12.25 × 19 × 14.5 in.) H × W × D Weight 11 kg (25 lb.
CC9600 Chassis User Guide 4 CommPlete Communications Server
2 Installation CommPlete Communications Server 5
CC9600 Chassis User Guide Introduction This chapter contains only general information about installing the CC9600 chassis. The equipment should be installed only by a qualified service person. The CC9600 is designed to be installed in a standard 19-inch-wide rack cabinet. Figure 1 shows a fully loaded chassis with one controller card, two power supplies, and a full complement of RASCards and modem cards. Power Supply The chassis can work with one or two PS9600 power supplies.
Installation WARNING: Interconnection directly, or by way of other apparatus, of ports marked “SAFETY WARNING see instructions for use” with ports marked or not so marked may produce hazardous conditions on the network. Advice should be obtained from a competent engineer before such a connection is made. Installation • If the chassis is installed in a closed or multi-rack assembly, the operating temperature of the rack environment may be greater than the ambient temperature.
CC9600 Chassis User Guide Connections The rear of the CommPlete Communications Server provides connections to power, communications lines, and configuration hardware, as shown in Figure 2. Only the power connectors are part of the CC9600 chassis. The other connectors are mounted on removable cards or modules, and are documented in their respective user guides.
Appendix CommPlete Communications Server 9
CC9600 Chassis User Guide Appendix A Installing 3rd Party Software This appendix describes how to install the following software packages on the CommPlete Communication Server: • Citrix WinFrame • Microsoft Windows NT • SCO UNIX • Novell UNIXWare • BSD UNIX These procedures can be performed only by using the optional DA96002 load card. SCO UNIX, UNIXWare, and BSD UNIX procedures to be added later.
A Installing Third-Party Software 16. Enter 210 for the I/O address and 10 for the IRQ for the first card; Enter I/O address 220 and IRQ 11 for the second card; Enter I/O address 230 and IRQ 12 for the third card. 17. Leave the port numbers at the default settings, unless you have a good reason to change them. 18. Start setting up your WinStations (refer to the Citrix WinFrame documentation).
CC9600 Chassis User Guide Installing Microsoft Windows NT Software on the CommPlete This procedure tells how to install the Microsoft Windows NT software package on the CommPlete Communication Server. This procedure can be performed only by using the optional DA96002 load card. 12 1. Start the Windows NT install process using the procedures in the Windows NT documentation. 2.
A Installing Third-Party Software Installing SCO UNIX Software on the CommPlete This procedure steps you through the process of installing SCO UNIX software from The Santa Cruz Operation Inc.on the CommPlete system. This procedure can be performed only by using the optional DA96002 load card. Procedure to be added at a later date.
CC9600 Chassis User Guide Installing USL/Novell UNIXWare Software on the CommPlete This procedure steps you through the process of installing UNIXWare software from USL/Novell on the CommPlete system. This procedure can be performed only by using the optional DA96002 load card. Procedure to be added at a later date.
A Installing Third-Party Software Installing BSD UNIX Software on the CommPlete This procedure steps you through the process of installing BSD UNIX software from the University of California, Berkely on the CommPlete system. This procedure can be performed only by using the optional DA96002 load card. Procedure to be added at a later date.
CC9600 Chassis User Guide 16 CommPlete Communications Server