CC1600-Series Card Cages CC1600-Series Modem Racks Owner's Manual
Owner’s Manual 82047705 Revision F CC1600-Series Modem Rack This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved. Copyright© 1998, by Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc.
Contents Chapter 1 - Introduction and Description Introduction ................................................................................ 6 Description ................................................................................. 6 Technical Specifications ............................................................. 8 Chapter 2 - Installation Introduction .............................................................................. 10 Safety Warnings ............................................
iv
CC1600-Series Card Cages Chapter 1 - Introduction and Description
CC1600-Series Owner's Manual Introduction Welcome to the world of data communications. You have one of the finest modem racks made today. This owner's manual provides information that will help you to install and operate your Multi-Tech CC1600-Series Modem Rack. This manual covers the description of the modem rack, its technical specifications, power supply, procedures for modem installation, RS232C and phone line connections and powering up mode.
Chapter 1 - Introduction and Description The CC1600 is a generic rack that accommodates a variety of rackmount modems and DSUs. The CC1628 series is designed specifically for V.34 modems. Both rack models come in -11L and -21 versions. The -11L version connects to standard RJ11 telephone phone cords. The -21 version has three 50-pin connectors for dial-up and 2-wire or 4-wire leased lines. Both models are equipped for universal AC input or -48v DC.
CC1600-Series Owner's Manual Technical Specifications Rack Capacity: Up to 16 modems Connectors: IEC 320 Inlet Power Connector Dimensions: 19" wide x 7" high x 15" deep 48.26cm wide x 17.8cm high x 38.1cm deep Weights: Rack with one power supply: 21lbs. (9.5 kg) Rack with two power supplies and 16 modems: 30 lbs. (13.6 kg) Power Supply Input: 8 PS1600 - 90 to 245 Volts AC, 2.0 Amps PS1648 - -40 to -56 Volts DC, 2.
CC1600-Series Card Cages Chapter 2 - Installation
CC1600-Series Owner's Manual Introduction Multi-Tech rackmount modems are generally used in a central site computer environment (i.e., connected to a mini or mainframe computer) to automatically answer incoming calls from remote users. Command mode should be disabled unless you wish to give the modem commands. Leaving command mode enabled offers the possibility of a user calling into the modem and reconfiguring it, or causing it to dial out.
Chapter 2 - Installation Safety Recommendations The following safety recommendations should be observed when installing Multi-Tech CC1600-series modem racks. • Ensure proper installation of the CC1600-series modem racks in a closed or multi-unit enclosure by following the recommended installation as defined by the enclosure manufacturer. Do not place the CC1600-series modem rack directly on top of other equipment or place other equipment directly on top of the CC1600-series rack.
CC1600-Series Owner's Manual and TN (Telecommunications Network) circuits to TN circuits. Installation Perform the following procedure to install the CC1600-series modem rack and install up to 16 modems in the rack. 1. Unpack the rack and check all items against the shipping list to ensure that you have received the correct items. Rack Components A. B. C. Rack Power Cord Owner's Manual 2. Inspect the rack for visible shipping damage.
Chapter 2 - Installation Slot 1 Modem Component Side Rack Door Figure 2-1. Modem Installation 9. Firmly seat the modem card into the backplane connector. 10. Repeat steps 7 through 9 for the remaining modems. 11. Connect an RS232C cable to the DB25 connector (25-pin female connector) on the backplane of the rack. Start by connecting the RS232C cable to the right-most channel (slot 1) as viewed from the back of the rack.
CC1600-Series Owner's Manual Slot Number DB25 Connector (SELV Circuit) 16 13 1514 12 1110 7 9 8 6 3 54 2 1 RJ11 Connector (TN Circuit) Positive Lead Negative Lead 48 Volt Power Supply Figure 2-2. Cable Connections 12. If you are connecting your phone line directly to an RJ11 jack on the backplane of the rack, plug the telephone cord into the RJ11 jack on the appropriate modem.
Chapter 2 - Installation If you are connecting your phone lines (-21 series rack) to the 50-pin connector on the backplane of the rack, plug the appropriate phone cable into the appropriate 50-pin connector (RJ21X). RJ21X connectors are TN circuits. Note: Three 50-pin connectors are mounted on the back of the -21 series rack backplane. The left 50-pin connector (labeled Dial-Up/2-Wire Leased Line) is used to connect all the modems in the -21 series rack to dial-up phone lines.
CC1600-Series Owner's Manual Power Supply Installation The CC1600-series modem rack is configured with either a single power supply or two (hot-swappable, redundant) power supplies. A single power supply can maintain a full complement of 16 modems or DSUs. To install a power supply, perform the following procedure. 1. Unpack the power supply and check for visible shipping damage. If damage is observed, do not install the power supply; contact Multi-Tech's Technical Support for advice (refer to Chapter 3).
Chapter 2 - Installation 4. With a Phillips screwdriver, tighten the power supply screws. Warning: If only a single power supply is used, then the unused opening should have a power supply cover in place. 5. If a second power supply is being installed, repeat steps 1 through 4. 6. Return to the rack installation procedure to continue installing the rack.
CC1600-Series Owner's Manual 18
CC1600-Series Card Cages Chapter 3 - Service, Warranty and Tech Support
CC1600-Series Owner's Manual Introduction This chapter starts out with statements about your Multi-Tech CC1600-series modem rack 2-year warranty. The next section, Tech Support, should be read carefully if you have questions or problems with your CC1600-series modem rack. It includes the technical support telephone numbers, space for recording your product information, and an explanation of how to send in your CC1600-series modem rack should you require service.
Chapter 3 - Service, Warranty and Tech Support MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES AND UNDER NO CIRCUMSTANCES WILL ITS LIABILITY EXCEED THE PURCHASE PRICE FOR DEFECTIVE PRODUCTS. Tech Support Multi-Tech has an excellent staff of technical support personnel available to help you get the most out of your MultiTech product. If you have any questions about the operation of this unit, call 1-800-972-2439.
CC1600-Series Owner's Manual Service If your tech support specialist decides that service is required, your rack may be sent (freight prepaid) to our factory. Return shipping charges will be paid by Multi-Tech Systems. Include the following with your rack: • a description of the problem. • return billing and return shipping addresses. • contact name and phone number. • check or purchase order number for payment if the CC1600-series modem rack is out of warranty.
Chapter 3 - Service, Warranty and Tech Support The Multi-Tech BBS For customers who do not have Internet access, Multi-Tech maintains a bulletin board system (BBS) that mirrors its FTP site. Information available from the BBS includes new product information, product upgrade files, and problem-solving tips. The phone number for the Multi-Tech BBS is (800) 392-2432 (USA and Canada) or (612) 785-3702 (international and local).
CC1600-Series Owner's Manual 5. Select a file transfer protocol by typing the indicated letter, such as Z for Zmodem (the recommended protocol). 6. If you select Zmodem, the transfer will begin automatically. If you select another protocol, you may have to initiate the transfer yourself. (In most datacomm programs, the PAGE DOWN key initiates the download.) 7. When the download is complete, press ENTER to return to the File Menu. 8. To exit the BBS, type G and press ENTER.
Chapter 3 - Service, Warranty and Tech Support About the Internet Multi-Tech is a commercial provider on the Internet. If you prefer to receive service via the internet, you can contact Tech Support via e-mail at the following address: http://www.multitech.com/_forms/email_tech_support.htm Multi-Tech's presence includes a Web site at: http://www.multitech.com and an ftp site at: ftp://ftp.multitech.
CC1600-Series Owner's Manual 26
CC1600-Series Card Cages Appendices
CC1600-Series Owner's Manual Appendix A - Safety Requirements 1. No manual adjustments to the equipment are necessary for connection to mains power within rated voltage and frequency. 2. The power supply cord is intended to serve as the disconnect device. The socket-outlet must be installed near the equipment and be easily accessible. 3. To reduce the risk of shock, all openings should be covered during normal operation of the equipment. 4.
Appendix A - Safety Requirements Requisitos de seguridad 1. No son necesarios ajustes manuales del equipo para la conexión a la corriente de la red dentro del voltaje y frecuencia establecidas. 2. El conector de alimentación de energía sirve como dispositivo de desconexión. La toma de corriente se debe instalar cerca del equipo y tener un acceso sencillo. 3. Para reducir el riesgo de sacudida eléctrica, todas las aberturas deben estar cubiertas durante el manejo normal del equipo. 4.
CC1600-Series Owner's Manual Mains Wiring Instructions (U.K.) When wiring the mains plug, the following instructions must be followed: • the core which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol , or coloured green and yellow. • the core which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
Appendix A - Safety Requirements Requisitos de potencia C.A. 90-245 V, 50/60 Hz, 2.0 Amp DC 40-56V, 2.5A ATTENCION: Adviertase que los requisitos respecto a medidas de seguridad no quedan satisfechos a menos que este equipo eléctrico esté conectado a una toma de corriente mural conectada a tierra. Stromaufnahme AC 90-245V, 50/60 Hz, 2.0A DC 40-56V, 2.5A VORSICHT: Die Sicherheitsvorschriften sind nur erfüllt, wenn das Gerät an eine geerdete Wandsteckdose angeschlossen ist.
CC1600-Series Owner's Manual Appendix B - Cabling Introduction This appendix shows the cable and connector pinouts for the CC1600 rack. Dial/Leased Splitter The Dial/Leased Splitter consists of an RJ11 plug at one end of a 5-inch cable that plugs into the RJ11 jack on the backplane of the CC1600 rack. The other end of the cable has two RJ11 jacks that connect to a leased line and, if dial back-up is used, the Dial jack provides that connection.
Appendix A - Safety Requirements -21 Series Connector Pinouts Three 50-pin connectors are used on the -21 series rack; they are located at the top of the backplane. The Dial-up/2Wire Leased connector is to the left (as viewed from behind the chassis), the 4-wire Receive connector is in the center, and the 2-Wire Leased/4-Wire Transmit connector is on the right side of the backplane. Pinouts for each connector are shown below.