PARTS AND OPERATION MANUAL OPERATION AND PARTS MANUAL WHISPERWATTTM SERIES MODEL TLG-12SPX4 60 Hz GENERATOR Revision #1 (12/17/09) THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
Diesel engine exhaust and some of PAGE 2 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
NOTE PAGE 1 TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TABLE OF CONTENTS MQ POWER TLG-12SPX4 WHISPER WATTTM GENERATOR WHISPERW California Proposition 65 Warning ..................................... 2 Table Of Contents ............................................................. 4 Parts Ordering Procedures ............................................... 5 Specifications ................................................................... 6 Dimensions (Top, Side, Front) .......................................... 7 Safety Message Alert Symbols ...................
www.mqpower.com PARTS ORDERING PROCEDURES Ordering parts has never been easier! Choose from three easy options: Order via Internet (Dealers Only): Best Deal! Effective: January 1st, 2006 If you have an MQ Account, to obtain a Username and Password, E-mail us at: parts@multiquip. com. Order parts on-line using Multiquip’s SmartEquip website! N View Parts Diagrams N Order Parts N Print Specification Information To obtain an MQ Account, contact your District Sales Manager for more information.
TLG-12SPX4 — SPECIFICATIONS Table 1. Generator Specifications Model TLG-12SPX4 Type Revolving field, Protection type Synchronous Generator Phase Single Phase Standby Output 13 KW Prime Output 12 KW Voltage 240V/120 Frequency 60 Hz S pe e d 3600 r pm Power Factor 1.0 Table 2. Engine Specifications Model KUBOTA D902 Type 4 Cycle, water-cooled, swirl combustion chamber type No. of Cylinders 3 cylinders Bore x Stroke 2.83 in. x 2.9 in. (72 mm x 74 mm) Rated Output 20.
TLG-12SPX4 — DIMENSIONS (TOP, SIDE AND FRONT) Figure 1. Dimensions TABLE 3. DIMENSIONS Reference Letter Dimension ft. (mm.) A 23.23 in. (590 mm.) B 17.52 in. (445 mm.) C 19,69 in. (500 mm.) D 55.12 in. (1,400 mm.) E 33.46 in. (850 mm.) F 27,17 in. (6910 mm.) TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG-12SPX4 — SAFETY MESSAGE ALERT SYMBOLS FOR YOUR SAFETY AND THE SAFETY OF OTHERS! Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others. NOTE This Owner's Manual has been developed to provide complete instructions for the safe and efficient operation of the MQ Power Generator.
TLG-12SPX4 — SAFETY MESSAGE ALERT SYMBOLS WARNING - ROTATING PARTS NEVER operate equipment with covers, or guards removed. Keep fingers, hands, hair and clothing away from all moving parts to prevent injury. CAUTION - ACCIDENTAL STARTING ALWAYS place the engine ON/OFF switch (MPEC) in the OFF/RESET position when the generator is not in use. CAUTION - OVER-SPEED CONDITIONS NEVER tamper with the factory settings of the engine governor or settings.
TLG-12SPX4 — RULES FOR SAFE OPERATION DANGER - READ THIS MANUAL! Failure to follow instructions in this manual may lead to serious injury or even DEATH! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only. The following safety guidelines should always be used when operating the generator. ■ NEVER use accessories or attachments, which are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.
TLG-12SPX4 — RULES FOR SAFE OPERATION ■ ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using generators. ■ NEVER leave the generator unattended, turn off engine when unattended. ■ Unauthorized equipment modifications will void all warranties. ■ ALWAYS ensure generator is on level ground before use. ■ DO NOT place hands or fingers inside generators engine compartment when engine is running.
TLG-12SPX4 — RULES FOR SAFE OPERATION WARNING - BURN HAZARDS To prevent burns, DO NOT touch or open any of the below mentioned components while the engine is running or immediately after operations. Always allow sufficient time for the engine and generator to cool before performing maintenance.
TLG-12SPX4 — RULES FOR SAFE OPERATION Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a posion you cannot see or smell 20A 2900 120 V OFF GA-2.9R 120V 20A 2900 120V ON OFF AC CIRCUIT BREAKER 20A 2900 120 V GA-2.9R 22A NEVER grab or touch a live power cord with wet hands, the possibility exist of electrical shock, electrocution, and even death! DANGER 120 V ON GA-2.
TLG-12SPX4 — RULES FOR SAFE OPERATION If your generator is trailer mounted, please read the towing and safety requirements listed below. Towing and Transporting Safety To reduce the possibility of an accident while transporting the generator on public roads, always make sure the trailer that supports the generator and the towing vehicle are in good operating condition and both units are mechanically sound.
TLG-12SPX4 — INSTALLATION Figure 2. Typical Generator Grounding Application 1 TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG-12SPX4 — INSTALLATION Outdoor Installation Generator Grounding Install the generator in a area that is free of debris, bystanders, and overhead obstructions. Make sure the generator is on secure level ground so that it cannot slide or shift around. Also install the generator in a manner so that the exhaust will not be discharged in the direction of nearby homes. To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.
TLG-12SPX4 — GENERAL INFORMATION TLG-12SPX4 Whisperwatt™ Series Familiarization Generator The MQ Power Model TLG-12SPX4 is a 13 kW generator (Figure 3) that is designed as a high quality portable (requires a trailer for transport) power source for telecom sites, lighting facilities, power tools, submersible pumps and other industrial and construction machinery.
TLG-12SPX4 — MAJOR COMPONENTS Table 4. Generator Major Components ITEM NO. Figure 3. Major Components DESCRIPTION 1 Fuel Tank Assembly 2 Engine and Radiator Assembly 3 Muffler Assembly 4 Generator Assembly 5 Battery Assembly 6 Generator Control Panel Assembly PAGE 18 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG-12SPX4 — GENERATOR CONTROL PANEL Figure 4. Generator Control Panel 1 TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG-12SPX4 — GENERATOR CONTROL PANEL The definitions below describe the controls and functions of 6. the Generator Control Panel (Figure 4). Hour Meter – Indicates the number of hours machine has been in use. 1. Frequency Meter – Indicates the output frequency in 7. hertz (Hz). Normally 60 Hz. Fuel Guage – Indicates the amount of fuel in the Generator. 2. AC Ammeter – Indicates the amount of current the load 8. is drawing from the generator.
TLG-12SPX4 — OUTPUT TERMINAL PANEL FAMILIARIZATION Output Terminal Panel Output Terminal Familiarization The Output Terminal Panel (Figure 5) shown below is located The “Output Terminal Panel ” (Figure 5) is provided with the on the right-hand side (left from control panel) of the generator. following: Lift up on the cover to gain access to receptacles and terminal ■ 120V GFCI receptacle @ 20 amp lugs.
TLG-12SPX4 — OUTPUT TERMINAL PANEL FAMILIARIZATION L5-30R Twist Lock 120 VAC Receptacle (Option) 120 VAC GFCI Receptacle This120 VAC, 20 amp GFCI (Duplex Nema 5-20R) receptacle There is one L5-30R, 120 VAC 30 amp auxilliary twist-lock can be used anytime the generator is in operation. Pressing receptacle (Figure 8) provided on the output terminal panel. the reset button resets the GFCI receptacle after being tripped.
TLG-12SPX4 — OUTPUT TERMINAL PANEL FAMILIARIZATION Connecting Loads Loads can be connected to the generator by the Ouput Terminal Lugs or the convenience receptacles (Figure 11). Make sure to read the operation manual before attempting to connect a load to the generator. To protect the output terminals from overload, a 3-pole, 50A main circuit breaker is provided. Make sure to switch ALL circuit breakers to the OFF position prior to starting the engine. Figure 11.
TLG-12SPX4 — LOAD APPLICATION/MAXIMUM AMPERAGE Single Phase Load Always be sure to check the nameplate on the generator and equipment to insure the wattage, amperage, frequency, and voltage requirements are satisfactorily supplied by the generator for operating the equipment. Generally, the wattage listed on the nameplate of the equipment is its rated output.
TLG-12SPX4 — SETUP Fuel Check Circuit Breakers To protect the generator from an overload, a 3-pole, 50 amp, main circuit breaker has been provided. Make sure to switch ALL circuit breakers to the OFF position prior to starting the engine. Lubrication Oil Fill the engine crankcase with lubricating oil through the filler hole, but DO NOT overfill. Make sure the generator is level. and verify that the oil level is maintained between the two notches (Figure 12) on the dipstick.
TLG-12SPX4 — SETUP Refueling Procedure: NOTE WARNING - RESPIRATORY HAZARDS Diesel fuel and its vapors are dangerous to your health and the surrounding environment. Avoid skin contact and/or inhaling fumes. 1. Level Tanks – Make sure fuel cells are level with the ground. Failure to do so will cause fuel to spill from the tank before reaching full capacity (Figure 14). 3. If generator is equipped with an environmental fuel tank, reference Figures 16 and 17.
TLG-12SPX4 — SETUP Coolant (Antifreeze/Summer Coolant/Water) KUBOTA recommends antifreeze/summer coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the KUBOTA Engine Owner's Manual for further details. Cleaning the Radiator The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air.
TLG-12SPX4 — SETUP When connecting battery do the following: Battery This unit is of negative ground DO NOT connect in reverse. 1. NEVER connect the battery cables to the battery terminals when the ignition switch is in the ON position Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level are not 2. Place a small amount of battery terminal treatment properly maintained. Add only distilled water when compound around both battery terminals.
TLG-12SPX4 — GENERATOR START-UP PROCEDURE Before Starting CAUTION - LETHAL EXHAUST HAZARD The engine's exhaust contains harmful emissions. ALWAYS have adequate ventilation when operating. Direct exhaust away from nearby personnel. Start-up Procedure 1. Place engine throttle lever (Figure 22) in the START/IDLE position (low speed). WARNING - STARTING THE GENERATOR NEVER! manually start the engine with the main, GFCI or auxiliary circuit breakers in the ON (closed) position. Figure 22.
TLG-12SPX4 — GENERATOR START-UP PROCEDURE (MANUAL) 5. Pull the throttle lever (Figure 24) and turn to the right to increase engine speed. 8. The ammeter (Figure 28) will indicate zero amps with no load applied. When a load is applied, the ammeter will indicate the amount of current that the load is drawing from the generator. Figure 24.Throttle Lever (High Speed) 6. The generator’s frequency meter (Figure 25) displays the 60 cycle output frequency in HERTZ. Figure 28. Ammeter (No Load) 7.
TLG-12SPX4 — GENERATOR SHUT-DOWN PROCEDURES WARNING - SHUTTING DOWN THE GENERATOR NEVER stop the engine suddenly except in an emergency. Normal Shutdown Procedure Emergency Shutdown Procedure 1. Turn the ignition key counter-clockwise to the STOP position. When the engine has stopped, remove key. Place key in a safe place where it will not be lost. To shutdown the generator use the following procedure: 2. Place both the main circuit breaker as shown in (Figure 31) to the OFF position. 1.
TLG-12SPX4 — MAINTENANCE 10 Hrs DAILY TABLE 11.
TLG-12SPX4 — MAINTENANCE Flushing Out Radiator and Replacing Coolant Air Removal If air enters the fuel injection system of a diesel engine, Open both cocks located at the crankcase side and at the lower part of the radiator and drain coolant. Open the starting becomes impossible. After running out of fuel, or radiator cap while draining. Remove the overflow tank after disassembling the fuel system, bleed the system and drain. according to the following procedure.
TLG-12SPX4 — TRAILER MAINTENANCE Brakes Trailer brakes should be inspected the first 200 miles of operation. This will allow the brake shoes and drums to seat properly. After the first 200 mile interval, inspect the brakes every 3,000 miles. If driving over rough terrain, inspect the brakes more frequently. Figure 32 displays the major hydraulic surge brake components that will require inspection and maintenance.
TLG-12SPX4 — TRAILER MAINTENANCE Tires/Wheels/Lug Nuts Tires and wheels are a very important and critical components of the trailer. When specifying or replacing the trailer wheels it is important the wheels, tires, and axle are properly matched. CAUTION - EYESIGHT HAZARD Suspension The leaf suspension springs and associated components (Figure 33) should be visually inspected every 6,000 miles for signs of excessive wear, elongation of bolt holes, and loosening of fasteners.
TLG-12SPX4 — TRAILER MAINTENANCE Lug Nut Torque Requirements It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows: 1. Start all wheel lug nuts by hand. 2. Torque all lug nuts in sequence (see Figure 34). DO NOT torque the wheel lug nuts all the way down. Tighten each lug nut in 3 separate passes as defined by Table 15. 3.
TLG-12SPX4 — GENERATOR WIRING DIAGRAM Figure 35. Generator Wiring Diagram 1 TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG-12SPX4 — ENGINE WIRING DIAGRAM Figure 36. Engine Wiring Diagram PAGE 38 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG-12SPX4 — TROUBLESHOOTING (ENGINE) Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 16 shown below for diagnosis of the engine. If the problem cannot be remedied, consult our company's business office or service plant. TABLE 16. ENGINE TROUBLESHOOTING SYMPTOM Engine does not star t. POSSIBLE PROBLEM SOLUTION No fuel? Replenish fuel. Air in the fuel system? Bleed system.
TLG-12SPX4 — TROUBLESHOOTING (ENGINE) TABLE 16. ENGINE TROUBLESHOOTING (CONTINUED) SYMPTOM POSSIBLE PROBLEM Engine revolution is not smooth. Either white or blue exhaust gas is observed. Either black or dark gray exhaust gas is observed. Deficient output. SOLUTION Fuel filter clogged or dir ty? Clean or change. Air cleaner clogged? Clean or change. Fuel leak due to loose injection pipe retaining nut? Tighten nut. Injection pump malfunctioning? Repair or replace.
TLG-12SPX4 — TROUBLESHOOTING (GENERATOR) Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 17 shown below for diagnosis of the generator. If the problem cannot be remedied, consult our company's business office or service plant. TABLE 17.
TLG - 12SPX4 — EXPLANATION OF CODE IN REMARKS COLUMN The following section explains the different symbols and remarks used in the Parts section of this manual. Use the help numbers found on the back page of the manual if there are any questions. The contents and part numbers listed in the parts section are subject to change without notice. Multiquip does not guarantee the availibility of the parts listed. PART NO. PART NAME QTY. 12345 BOLT ....................... 1 .... WASHER, 1/4 IN. ...........
TLG - 12SPX4 — SUGGESTED SPARE PARTS TLG-12SPX4 WHISPER WATTGENRATOR W/KUBOTA D902 DIESEL ENGINE 1 TO 3 UNITS Qty. P/N Description 1 ......... B0310502103 ..... HOSE, RADIATOR UPPER 1 ......... B5310502203 ..... HOSE, RADIATOR LOWER 6 ......... 1585332435 ....... FILTER, OIL 5 ......... 1523143563 ....... ELEMENT, FUEL FILTER 3 ......... 0602046335 ....... ELEMENT, AIR 1 ......... 1747297011 ....... FAN BELT 1 ......... A9924800024 ..... CAP AND FILTER, FUEL TANK 1 ......... 1584139010 ....... SWITCH, OIL.
TLG - 12SPX4 — GENERATOR ASSY. GENERATOR ASSY. PAGE 44 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — GENERATOR ASSY. GENERATOR ASSY. NO. 1 1-1 1-2 1-3 1-4 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 19A 20 21 22 23 24 PART NO. D4110000203 0601820037 0601822638 0071206307 0080000035 0012410030 D4111100103 0017108025 D4153100102 8521384003 D4153000202 B0137000003 0017105035 D4153400403 D4131200004 0040012000 0041212000 0030012000 B0131300104 0017108030 0012410025 D4155400004 0017106040 0037906000 B0132100303 B032100203 0012310025 B9310600104 0207010000 PART NAME QTY.
TLG - 12SPX4 — CONTROL PANEL ASSY. CONTROL PANEL ASSY. PAGE 46 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — CONTROL PANEL ASSY. CONTROL PANEL ASSY. NO. 1 2 3 4 5 6 7 8 8A 9 9A 10 11 11A 11B 12 13 14 15 16 16A 16B 17 18 19 20 21 22 23 24 25 26 27 27A 27B 27C 28 29 30 31 32 33 34 35 36 37 PART NO.
TLG - 12SPX4 — CONTROL PANEL ASSY. CONTROL PANEL ASSY. PAGE 48 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — CONTROL PANEL ASSY. CONTROL PANEL ASSY. NO. 38 39 40 41 42 43 44 44A 45 PART NO. B0354400003 3032143004 0601812598 0601811031 0601811033 0601812565 0027104012 0207004000 0601815109 PART NAME THROTTLE CABLE SPRING RECEPTACLE, 5-20R 120V 20A RECEPTACLE, L5-30R 125V 30A RECEPTACLE, L6-30R 250V 30A RECEPTACLE, CS6369125/250A 50A MACHINE SCREW HEX NUT GROUND TERMINAL QTY. 1 1 1 1 1 1 8 8 1 REMARKS 1 TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — ENGINE AND RADIATOR ASSY. ENGINE & RADIATOR ASSY. PAGE 50 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — ENGINE AND RADIATOR ASSY. ENGINE & RADIATOR ASSY. NO. 1 1A 1-1 2 3 4 5 6 7 7-1 8 9 10 11 12 13 14 15 16 17 18 19 20 20A 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 PART NO.
TLG - 12SPX4 — ENGINE AND RADIATOR ASSY. ENGINE & RADIATOR ASSY. PAGE 52 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — ENGINE AND RADIATOR ASSY. ENGINE & RADIATOR ASSY. NO. 42 43 44 45 46 47 48 49 PART NO. 0016906025 0016906016 0193600800 0605515094 0314900350 0314900430 1584139010 0314900430 PART NAME HEX HEAD BOLT HEX HEAD BOLT HOSE HOSE BAND RUBBER SEAL RUBBER SEAL SWITCH, OIL SWITCH, THERMOMETER QTY. 1 2 1 2 2 2 1 1 REMARKS 1 TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — BATTERY ASSY. BATTERY ASSY. PAGE 54 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — BATTERY ASSY. BATTERY ASSY. NO. 1 2 3 4 5 6 7 8 9 10 PART NO. 0165105524 8722251004 7552253004 7872251004 0037806000 0040006000 0041606000 0602220312 0602220313 0602220600 PART NAME BATTERY BATTERY SHEET BATTERY BAND BATTERY BOLT WING NUT SPRING WASHER PLAIN WASHER TERMINAL ASSY., NO. 15L(+) TERMINAL ASSY., NO. 15L(-) TERMINAL CAP QTY. 1 1 1 2 2 2 2 1 1 1 REMARKS 1 TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — MUFFLER ASSY. MUFFLER ASSY. PAGE 56 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — MUFFLER ASSY. MUFFLER ASSY. NO. 1 2 3 4 5 6 7 8 PART NO. B0331000503 0016908020 0016908020 B0333002303 1526312371 D9304000004 0207008000 0016908030 PART NAME QTY. REMARKS MUFFLER 1 HEX HEAD BOLT 4 HEX HEAD BOLT 2 EXHAUST PIPE 1 GASKET ......................................................... 1 .......... REPLACES P/N 0602320153 GASKET 6 HEX NUT 4 HEX HEAD BOLT 2 1 TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — FUEL TANK ASSY. FUEL TANK ASSY. PAGE 58 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — FUEL TANK ASSY. FUEL TANK ASSY. NO. 1 1-1 2 2A 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 18A 19 20 21 22 23 24 25 26 27 PART NO. B0363000103 A9924800024 E2924300214 E1924300184 0022905015 B0483000303 0222100260 0016908020 B0364200104 0805003414 0016908020 0207308000 B9312400004 7812014003 0802011104 0150000018 0016906016 0199900930 0605515094 1553143012 1523143563 B0366700504 0016906020 0016908065 0966180160 0966180300 0966140320 0966140320 1430142753 1497142751 PART NAME QTY.
TLG - 12SPX4 — ENCLOSURE ASSY. ENCLOSURE ASSY. PAGE 60 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — ENCLOSURE ASSY. ENCLOSURE ASSY. NO. 1 1A 2 2A 3 3A 4 5 5A 6 7 8 9 10 11 12 12A 13 14 14A 15 16 17 18 19 20 21 22 23 23A 24 25 26 27 27A 28 29 29A 30 30A 31 32 32A 33 PART NO.
TLG - 12SPX4 — ENCLOSURE ASSY. ENCLOSURE ASSY. PAGE 62 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — ENCLOSURE ASSY. ENCLOSURE ASSY. NO. 34 34A 35 35A 36 36A 37 38 39 40 41 42 43 44 PART NO. 0021806016 0030006000 0845047204 0845045004 0845047104 0845045004 0016908020 0845031504 8511864604 0016906016 0016908020 0600500090 0021106016 0601850541 PART NAME MACHINE SCREW HEX NUT HINGE WASHER HINGE WASHER HEX HEAD BOLT CAP PLATE HEX HEAD BOLT HEX HEAD BOLT EMBLEM MACHINE SCREW LOCK QTY. 4 4 2 2 2 2 8 4 1 4 1 1 2 2 REMARKS 1 TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — RUBBER SEALS ASSY. RUBBER SEALS ASSY. PAGE 64 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — RUBBER SEALS ASSY. RUBBER SEALS ASSY. NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 PART NO. 0314900690 0314900560 0314900920 0229400590 0229400900 0229400550 0314900635 0314900150 0229400290 0229400585 0229400250 0227500380 0227500080 PART NAME RUBBER SEAL RUBBER SEAL RUBBER SEAL RUBBER SEAL RUBBER SEAL RUBBER SEAL RUBBER SEAL RUBBER SEAL RUBBER SEAL RUBBER SEAL RUBBER SEAL RUBBER SEAL RUBBER SEAL QTY. 1 2 2 2 2 1 2 2 1 2 1 2 2 REMARKS 1 TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — NAME PLATE ASSY. NAME PLATE ASSY. PAGE 66 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — NAME PLATE ASSY. NAME PLATE ASSY. NO. 1-1 1-2 1-3 PART NO. 7440611013 6390671104 B9521100404 PART NAME QTY. REMARKS DECAL : OPERATING PROCEDURE ...........................1 ......... S-1742B DECAL : IMPORTANT “ CHECK DAILY “ ......................1 ......... S-2377 DECAL : SAFETY INSTRUCTIONS .............................1 .........
TLG - 12SPX4 — NAME PLATE ASSY. NAME PLATE ASSY. PAGE 68 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
TLG - 12SPX4 — NAME PLATE ASSY. NAME PLATE ASSY. NO. 7-7 7-8 7-9 7-10 7-11 7-12 7-13 7-14 7-15 PART NO. B0560100004 B0560100604 B0560100204 B0560100304 B0560100504 B0560100404 B0560100104 B0560100703 B9505000304 PART NAME QTY. REMARKS STRIPE ........................................................................1 ......... B06010000 STRIPE ........................................................................1 ......... B06010060 STRIPE ..................................................................
TERMS AND CONDITIONS OF SALE — PARTS PAYMENT TERMS 5. Parts must be in new and resalable condition, in the original Multiquip package (if any), and with Multiquip part numbers clearly marked. 6. The following items are not returnable: Multiquip reserves the right to quote and sell direct to Government agencies, and to Original Equipment Manufacturer accounts who use our products as integral parts of their own products. a. SPECIAL EXPEDITING SERVICE Terms of payment for parts are net 30 days.
NOTE PAGE 1 TLG-12SPX4— OPERATION AND PARTS MANUAL — REV.
PARTS AND OPERATION MANUAL OPERATION AND PARTS MANUAL HERE’S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING MULTIQUIP CORPORATE OFFICE 18910 Wilmington Ave Tel. (800) 421-1244 Carson, CA 90746 Fax (800) 537- 3927 Contact: mq@multiquip.com Web: www.multiquip.com MQ Power 1800 Water Ridge Rd. Tel. (800) 883-2551 Suite 500/600 Fax (972) 315-1847 Lewisville, TX 75057 Contact: mqpower@multiquip.com Web: www.mqpower.