User's Manual

PAGE 10 — SS233 SUBMERSIBLE PUMP • OPERATION AND PARTS MANUAL — REV. #2 (03/22/10)
COMPONENTS
3
3
1
3
4
5
6
7
2
Figure 1. Submersible Pump Components
Figures 1 shows the location of the basic components
for the SS233 submersible pump. Listed below is a brief
explanation of each component.
1. AC Power Cable — This unit is supplied with a 20 ft.
(6.1 meters) AC power cable. Always check the cable
for signs of wear. NEVER! use a defective power cable.
Replace the cable immediately if the cable is worn or
defective.
2. 2-Inch NPT Fitting Install this fitting into the
discharge port of the pump
3. Discharge Port Connect a 2" NPT hose to this port.
Remember to adequately support the discharge hose
to avoid stress on the pump.
4. Thermal Overload Protection — This pump has an
internal thermal overload protection device that will
shut-down the motor in the event of high operating
temperatures. The motor will automatically restart once
the temperature returns to an acceptable operating
temperature.
5. Strainer Base This strainer base is made of durable
plastic. DO NOT pump large objects or debris with
this pump. This pump is for pumping water only. For
de-watering purposes, always place the strainer base
on a platform.
6. Electric Motor This unit utilizes a single-phase,
115 V, 0.5 HP electric motor. Consult with a licenced
electrician before connecting motor to a power source.
Observe all city and local safety codes.
7. Volute/Impeller Impellers are constructed of thermo
plastic to minimizes wear and prolong service life.