User's Manual

PAGE 36 — GA9.7HE 60 HZ GENERATOR• OPERATION AND PARTS MANUAL — REV. #1 (04/29/10)
GA9.7HE— NAMEPLATE AND DECALS ASSY.
240
V
120
ON
OFF
ON
OFF
GA-9.7HE
AC CIRCUIT
BREAKER
(for main)
15A
30A
30A
120V
240V
120/240V
START
BUTTON
OPERATION
SWITCH
IDLE CONTROL
SWITCH
for 120V
for 120V
20A
for 240V
for 120/240V
AC CIRCUIT BREAKER
AC VOLTMETER
9700
OFF OFF
35A
35A
S-1123
CAUTION
HOT PARTS can burn skin.
DO NOT touch until the
has sufficiently cooled.lamp
B90400030
1. Before starting check the oil and fuel level.
2. Switch the circuit breaker to the “OFF” position.
3.
. Turn the operation switch to the “ON” position
. After the engine starts, gradually push in the choke knob.
. Run the generator for 3-5 minutes without load.
. Check for any abnormal noise or smell.
. Switch the circuit breaker to the “ON” position.
. When stopping, cut-off the load and allow the unit
to cool for 2-3 minutes before stopping engine.
1 .Turn the operation switch to the “OFF” position.
Pull the choke knob.
4
and push the start button to start the engine.
5
6
7
8
9
0
OPERATING INSTRUCTIONS
D25200040B
To avoid injury,
you MUST read
and understand
operator’s manual
before using this
machine.
Ask for training
as needed.
This machine to
be operated by
qualified
personnel only.
WARNING
Only qualified personnel should
install, use or service this
equipment.
DANGEROUS
GAS
S-4984
WARNING
Only operate machine in well ventilated
areas.
DO NOT inhale exhaust gases.
Only qualified personnel should
install, use or service this
equipment.
S-4985
DANGER
Do not touch output terminals or
internal wiring while unit is operating.
Turn off power before servicing.
Only qualified personnel should
install, use or service this
equipment.
ELECTRICAL
SHOCK
HAZARD
CAUTION
OPERATE AT
3600 RPM ONLY
( )
FULL THROTTLE
DAMAGE MAY RESULT IF
OPERATED AT LOWER SPEEDS
WARNING
B e f o r e c o n n e c t i n g t h i s
g e n e r a t o r t o a n y b u i l d i n g s
e l e c t r i c a l s y s t e m , a l i c e n s e d
e l e c t r i c i a n m u s t i n s t a l l a n
i s o l a t i o n ( t r a n s f e r ) s w i t c h .
S e r i o u s i n j u r y o r d e a t h m a y
r e s u l t w i t h o u t t h i s t r a n s f e r
s w i t c h .
A91110010
DANGER
Using a generator indoors .
Utilser un générateur à l’ intérieur VOUS TUERA EN QUELQÙES MINUTES.
CAN KILL YOU IN MINUTES
120
V
OFF
GAC-2.2H
POWEREDby
HondaEngines
120V
15A
GRPRISEDE
TERRE
ACCIRCUITBREAKER
INTERRUPTEURDE
COURANTPRINCIPAL
NEUTRALBONDEDTOFRAME
NEUTREMISALAMASSEA
LACARCASSEDUMOTEUR
211052
120
V
OFF
GAC-2.2H
POWEREDby
HondaEngines
120V
15A
GRPRISEDE
TERRE
ACCIRCUITBREAKER
INTERRUPTEURDE
COURANTPRINCIPAL
NEUTRALBONDEDTOFRAME
NEUTREMISALAMASSEA
LACARCASSEDUMOTEUR
211052
120
V
OFF
GAC-2.2H
POWEREDby
HondaEngines
120V
15A
GRPRISEDE
TERRE
ACCIRCUITBREAKER
INTERRUPTEURDE
COURANTPRINCIPAL
NEUTRALBONDEDTOFRAME
NEUTREMISALAMASSEA
LACARCASSEDUMOTEUR
211052
NEVER use in enclosed or partially
enclosed areas.
Utilisation INTERDITE dans un
espace clos ou partiellement clos.
ONLY use outdoors and away from
open windows, doors, and vents.
Utilisation UNIQUEMENT à l’ extér leur
portes et trous d’ aération
Exhaust contains carbon monoxide, a poison gas you cannot see or smell.
Les gaz d’ échappement contiennent du monoxyde de carbon, un gaz toxique
invisible et inodore.
A90400001
GROUND ROD
FOR EARTH
GROUND
CONNECT TO
BUILDING
GROUND
IF REQUIRED
8 FT. MINIMUM
REFERENCE
NEC 250-52(C)
ACCIRCUIT
BREAKER
120/240V
30A
120V
30A 20A
20A
0N
OFF
IDLE
CONTROL
OPERATION
SWITCH
ON
OFF
FULLPOWER
SWITCH
120V
120V/240V
120
V
OFF
21A
GA-6H
6000
GROUND
SCREW
GROUND
CABLE
#8 MINIMUM
DANGER
THE POSSIBILITY EXISTS OF IF
GENERATOR/WELDER IS NOT PROPERLY GROUNDED.
ALWAYS CONNECT EARTH GROUND (GROUND
ROD) TO GENERATOR GROUND POINT.
ELECTROCUTION
FOR FURTHER GROUNDING
INSTRUCTIONS, READ MANUAL
D9531100104
WARNING
Operation of this equipment may create
sparks that can start fires around dry
vegetation.
A spark arrestor may be required.
The operator should contact local fire
agencies for laws or regulation relating
to fire prevention requirements.
A91110010
CAUTION
H
L
Before starting the engine, check that the oil
level is within the indicated operating range.
If the level is the mark or
the mark, it is important to correct before
operating to avoid damage.
above belowH
L
OIL LEVEL GAUGE
GA-9.7HE
9700
OIL DRAIN
FUEL DRAIN
DANGER
EXPLOSIVE GASES
Cigarette flames or sparks could cause battery to explode. Always
shield eyes and face from battery. Do not charge or use booster cables
or adjust post connections without proper instructions and training.
POISON
CAUSES SEVERE BURNS
KEEP VENT CAPS TIGHT AND LEVEL
Contains sulfuric acid. Avoid contact with skin, eyes or clothing. In
event of accident flush with water and call a physician immediately.
KEEP OUT OF THE REACH OF CHILDREN
1
2
3
4
5
6
7
8
9
10
11
12
S/N 5619690 AND ABOVE