COOLANT (ANTIFREEZE/SUMMER COOLANT/
WATER)
ISUZU recommends ISUZU antifreeze/summer coolant for 
use in their engines, which can be purchased in concentrate 
(and mixed with 50% demineralized water) or pre-diluted. See 
the ISUZU Engine Owner’s Manual for further details.
Day-to-day addition of coolant is done from the recovery 
tank. When adding coolant to the radiator, DO NOT remove 
the radiator cap until the unit has completely cooled. See 
Table 10 for engine, radiator, and recovery tank coolant 
capacities. Make sure the coolant level in the recovery tank 
is always between the “H” and the “L” markings.
Operation in Freezing Weather
When operating in freezing weather, be certain the proper 
amount of antifreeze (Table 11) has been added.
 WARNING
If adding coolant/antifreeze mix to the 
radiator, DO NOT remove the radiator cap 
until the unit has completely cooled. The 
possibility of hot! coolant exists which can 
cause severe burns.
Table 10. Coolant Capacity
Engine and Radiator 14.3 Gal (54 liters)
Reserve Tank 1.3 Gal (4.92 liters)
Table 11. Anti-Freeze 
Operating Temperatures
Vol %
Anti-Freeze
Freezing Point
°C °F
50 -37 -34
NOTICE
When the antifreeze is mixed with water, the antifreeze 
mixing ratio must be less than 50%.
Cleaning the Radiator
The engine may overheat if the radiator fi ns become 
overloaded with dust or debris. Periodically clean the 
radiator fi ns with compressed air. Cleaning inside the 
machine is dangerous, so clean only with the engine turned 
off and the negative battery terminal disconnected.
AIR CLEANER
Periodic cleaning/replacement is necessary. Inspect it in 
accordance with the ISUZU Engine Owner’s Manual.
FAN BELT TENSION
A slack fan belt may contribute to overheating, or to 
insuffi cient charging of the battery. Inspect the fan belt for 
damage and wear and adjust it in accordance with the 
ISUZU Engine Owner’s Manual.
The fan belt tension is proper if the fan belt bends 10 to 15 
mm (Figure 33) when depressed with the thumb as shown 
below. 
Figure 33. Fan Belt Tension 
 CAUTION
NEVER place hands near the belts or fan 
while the generator set is running.