PARTS AND OPERATION MANUAL OPERATION AND PARTS MANUAL WHISPERWATTTM SERIES MODEL DCA-45SSIU3 60 Hz GENERATOR PARTS LIST NO. M1870300904 Revision #0 (11/30/05) THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
PAGE 2 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
HERE'S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING MQ POWER CORPORATE OFFICE 18910 Wilmington Ave. 800-421-1244 Carson, CA 90746 FAX: 310-632-2656 Email: mqpower@multiquip.com Internet: www.mqpower.com PARTS DEPARTMENT 800-427-1244 FAX: 800-672-7877 310-537-3700 FAX: 310-637-3284 SERVICE DEPARTMENT 800-835-2551 FAX: 310-638-8046 310-537-3700 TECHNICAL ASSISTANCE 800-835-2551 FAX: 310-638-8046 WARRANTY DEPARTMENT 800-835-2551, EXT. 279 FAX: 310-638-8046 310-537-3700, EXT.
DCA-45SSIU3 (60 Hz) — TABLE OF CONTENTS MQ POWER DCA-45SSIU3 (60 HZ) ISUZU BB4JG1T ENGINE WHISPER WATT™ GENERA TOR Generator Assembly ............................................ 52-53 GENERATOR WHISPERW California Proposition 65 Warning ..................................... 2 Here's How To Get Help .................................................... 3 Table Of Contents ............................................................. 4 Parts Ordering Procedures ...............................................
DCA-45SSIU3 (60 Hz) — PARTS ORDERING PROCEDURES When ordering parts, please supply the following information: ❒ ❒ ❒ ❒ ❒ ❒ ❒ Dealer account number Dealer name and address Shipping address (if different than billing address) Return fax number Applicable model number Quantity, part number and description of each part Specify preferred method of shipment: ✓ FedEx or UPS Ground Note: Unless otherwise indicated by customer, all ✓ FedEx or UPS Second Day or Third Day orders are treated as “Standard Orders”, and w
DCA-45SSIU3 (60 Hz) — SPECIFICATIONS Table 1. Generator Specifications Model DCA-45SSIU3 Type Revolving field, self ventilated, open protected type synchronous generator Armature Connection Star with Neutral Zig Zag Phase 3 Single Standby Output 47.3 KVA (37.8 KW) 27.3 KW Prime Output 45 KVA (36 KW) 26 KW Voltage 240V or 480V 240/120V Frequency 60 Hz Speed 1,800 rpm Power Factor 0.8 1 Aux. AC Power Single Phase, 60 Hz Voltage 120 VAC Output 4.8 KW (2.4 KW x 2) Table 2.
DCA-45SSIU3 (60 Hz) — DIMENSIONS (TOP, SIDE AND FRONT) TABLE 3. DIMENSIONS Reference Letter Dimension ft. (mm.) Reference Letter Dimension ft. (mm.) A 30.31 in. (770 mm.) F 74.80 in. (1,900 mm.) B 25.00 in. (635 mm.) G 49.21 in. (1,250 mm.) C 29.05 in. (738 mm.) H 35.43 in. (900 mm.) D 24.21 in. (615 mm.) E 29.05 in. (738 mm.) Figure 1. Dimensions 1 DCA-45SSIU3 (60 Hz) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — SAFETY MESSAGE ALERT SYMBOLS FOR YOUR SAFETY AND THE SAFETY OF OTHERS! Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others. This Operation and Parts Manual has been developed to provide complete instructions for the safe and efficient operation of the MQ Power Model DCA-45SSIU3 (60Hz) UltraSilent™ Generator.
DCA-45SSIU3 (60 Hz) — SAFETY MESSAGE ALERT SYMBOLS WARNING - ROTATING PARTS NEVER operate equipment with covers, or guards removed. Keep fingers, hands, hair and clothing away from all moving parts to prevent injury. CAUTION - ACCIDENTAL STARTING ALWAYS place the Engine ON/OFF switch in the OFF position and remove the ignition key when the pump is not in use. CAUTION - OVER-SPEED CONDITIONS NEVER tamper with the factory settings of the engine governor or settings.
DCA-45SSIU3 (60 Hz) — RULES FOR SAFE OPERATION DANGER - READ THIS MANUAL! Failure to follow instructions in this manual may lead to serious injury or even DEATH! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only. The following safety guidelines should always be used when operating the DCA-45SSIU3 (60 Hz) Whisperwatt ™ Generator General Safety: ■ DO NOT operate or service this equipment before reading this entire manual.
DCA-45SSIU3 (60 Hz) — RULES FOR SAFE OPERATION Generator Grounding To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground. Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.
DCA-45SSIU3 (60 Hz) — RULES FOR SAFE OPERATION Maintenance Safety ■ The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. Turn all circuit breakers OFF before performing maintenance on the generator. ■ NEVER lubricate components or attempt service on a running machine. ■ ALWAYS disconnect the NEGATIVE battery terminal before performing service on the generator.
DCA-45SSIU3 (60 Hz) — RULES FOR SAFE OPERATION Towing & Transporting Safety ■ The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing To reduce the possibility of an accident while transporting is not to exceed 15 MPH or less depending on type of the generator on public roads, always make sure the trailer terrain.
DCA-45SSIU3 (60 Hz) — GENERATOR DECALS The DCA-45SSIU3 (60 Hz) Whisperwatt™ Generator is equipped with a number of safety decals (Figures 2 and 3). These decals are provided for operator safety and maintenance information. The illustration below and on the preceding page show the decals as they appear on the machine. Should any of these decals become unreadable, replacements can be obtained from your dealer. Figure 2. Generator Decals PAGE 14 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — GENERATOR DECALS Figure 3. Generator Decals (Continued) 1 DCA-45SSIU3 (60 Hz) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — INSTALLATION Figure 4. Typical Generator Grounding Application PAGE 16 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — INSTALLATION Outdoor Installation Generator Grounding Install the generator in a area that is free of debris, bystanders, and overhead obstructions. Make sure the generator is on secure level ground so that it cannot slide or shift around. Also install the generator in a manner so that the exhaust will not be discharged in the direction of nearby homes. The installation site must be relatively free from moisture and dust.
DCA-45SSIU3 (60 Hz) — GENERAL INFORMATION DCA-45SSIU3 Whisperwatt™ Generator Familiarization The MQ Power Model DCA-45SSIU3 is a 36 kW, 60 Hz generator (Figure 5) that is designed as a high quality portable (requires a trailer for transport) power source for telecom sites, lighting facilities, power tools, submersible pumps and other industrial and construction machinery.
DCA-45SSIU3 (60 Hz) — MAJOR COMPONENTS Table 4. Generator Major Components ITEM NO. DESCRIPTION 1 Output Terminal Panel Assembly 2 Output Receptacles Assembly 3 Air Filter Assembly 4 Muffler Assembly 5 Fuel Tank Assembly 6 Engine Assembly 7 Battery Assembly 8 Generator Assembly 9 Engine Operating Panel Assembly 10 Generator Control Panel Assembly Figure 5. Major Components 1 DCA-45SSIU3 (60 Hz) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — GENERATOR CONTROL PANEL Figure 6. Generator Control Panel The definitions below describe the controls and functions of Located behind the generator control panel is the Generator the DCA-45SSIU3 (60 Hz) Whisperwatt™ Generator Control Control Box. This box contains some of the necessary electronic components required to make the generator Panel (Figure 6). 1. Main Circuit Breaker – This three-pole, 110A main function.
DCA-45SSIU3 (60 Hz) — ENGINE OPERATING PANEL Figure 7. Engine Operating Panel The definitions below describe the controls and functions of the 7. DCA-45SSIU3 (60 Hz) "Engine Operating Panel " (Figure 7). 1. Panel Light - Normally used in dark places or at night. When activated, panel will illuminate. When the generator 8. is not in use, turn the panel light switch to the ‘OFF’ position. Pre-heat Lamp - This indicates when the engine is ready for starting during cold weather operating conditions.
DCA-45SSIU3 (60 Hz) — OUTPUT TERMINAL PANEL FAMILIARIZATION Output Terminal Panel The Output Terminal Panel (Figure 8) shown below is located on the right-hand side (left from control panel) of the generator. Lift up on the cover to gain access to receptacles and terminal lugs.
DCA-45SSIU3 (60 Hz) — OUTPUT TERMINAL PANEL FAMILIARIZATION Figure 11. Voltage Regulator Control Knob Each auxiliary receptacle is protected by a 50 amp circuit breaker. These breakers are located directly above the GFCI receptacles. Remember the load output (current) on all three Figure 9. G.F.C.I. Receptacle receptacles is dependent on the load requirements of the Output Terminal Lugs.
DCA-45SSIU3 (60 Hz) — OUTPUT TERMINAL PANEL FAMILIARIZATION Connecting Loads Blower Fan Loads can be connected to the generator by the Output Terminal Lugs or the convenience receptacles (Figure 13). Make sure to read the operation manual before attempting to connect a load to the generator. To protect the output terminals from overload, a 3-pole, 110A main circuit breaker is provided. Make sure to switch ALL circuit breakers to the OFF position prior to starting the engine.
DCA-45SSIU3 (60 Hz) — LOAD APPLICATION Single Phase Load Three Phase Load Always be sure to check the nameplate on the generator and equipment to insure the wattage, amperage, frequency, and voltage requirements are satisfactorily supplied by the generator for operating the equipment. When calculating the power requirements for 3-phase power use the following equation: Generally, the wattage listed on the nameplate of the equipment is its rated output.
DCA-45SSIU3 (60 Hz) — GENERATOR OUTPUTS Voltage Selector Switch Generator Amperage The voltage selector switch (Figure 16) is located above Table 8 describes the generator’s current output capability the output terminal panel’s Hard Wire Hook-up Panel. It for both 1Ø-phase and 3Ø phase applications. has been provided for ease of voltage selection. Table 8. Generator Ampere Ratings DCA- 45SSIU3 KW KVA 120V 208V 240V Single Phase 26.0 N/A 108A x 2 N/A 108A 480V N/A Three Phase 36.
DCA-45SSIU3 (60 Hz) — GAUGE READING How to Read the Output Terminal Gauges. The gauges and selector switches on the control panel DO NOT effect the generator output. They are provided to help observe how much power is being supplied at the Output terminals lugs. Before taking a reading off either gauge, set the Voltage Selector Switch (Figure 17) to the position which produces the required voltage (For example, for 3Ø 240V, choose the center 3Ø 240/ 139V position on the voltage selector switch.
DCA-45SSIU3 (60 Hz) — OUTPUT TERMINAL PANEL CONNECTIONS UVWO Terminal Output Voltages 3Ø 208V/1Ø120V Output Terminal Lug Voltages Various output voltages can be obtained using the Output 1. Place the voltage selector switch in the 3Ø 240/139 Terminal Lugs.. The voltages at the terminals are depenposition as shown in Figure 25. dent on the position of the Voltage Selector Switch and the Use this position for adjustment of the Voltage Regulator Control Knob. 3Ø-208 or 1Ø120V.
DCA-45SSIU3 (60 Hz) — OUTPUT TERMINAL PANEL CONNECTIONS 3Ø 480/277 Output Terminal Lug Voltages 1Ø 240V/120V Output Terminal Lug Voltages 1. Place the voltage selector switch in the 3Ø 480/277 1. Place the voltage selector switch in the 1Ø 240/120 position as shown in Figure 27. position as shown in Figure 29. Figure 27. Voltage Selector Switch 480/277V Three-Phase Position Figure 29. Voltage Selector Switch 240/120V Single-Phase Position 2. Connect the load wires to the Output Terminal Lugs as 2.
DCA-45SSIU3 (60 Hz) — PRE-SETUP Circuit Breakers To protect the generator from an overload, a 3-pole, 110 amp, main circuit breaker is provided to protect the U,V, and W Output Terminals from overload. In addition two single-pole, 20 amp GFCI circuit breakers are provided to protect the GFCI receptacles from overload. Two 50 amp, 2-pole circuit breakers have also been provided to protect the auxiliary receptacles from overload.
DCA-45SSIU3 (60 Hz) — PRE-SETUP Refueling Procedure: 2. Remove fuel cap and fill fuel tank as shown in Figure 34. WARNING - RESPIRATORY HAZARDS Diesel fuel and its vapors are dangerous to your health and the surrounding environment. Avoid skin contact and/or inhaling fumes. 1. Level Tanks – Make sure fuel cells are level with the ground. Failure to do so will cause fuel to spill from the tank before reaching full capacity (Figure 33).
DCA-45SSIU3 (60 Hz) — PRE-SETUP Coolant (Isuzu Antifreeze/Summer Coolant/Water) Isuzu recommends Isuzu Antifreeze/Summer Coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the Isuzu Engine Owner's Manual for further details. Cleaning the Radiator The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air.
DCA-45SSIU3 (60 Hz) — PRE-SETUP Battery When connecting battery do the following: This unit is of negative ground DO NOT connect in reverse. 1. NEVER connect the battery cables to the battery terminals when the ignition is in the operate or start Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level are not position. properly maintained. Add only distilled water when 2.
DCA-45SSIU3 (60 Hz) — GENERATOR START-UP PROCEDURE 5. Place the voltage selector switch in the desired voltage position (Figure 41). Before Starting CAUTION - LETHAL EXHAUST HAZARD The engine's exhaust contains harmful emissions. ALWAYS have adequate ventilation when operating. Direct exhaust away from nearby personnel. WARNING - STARTING THE GENERATOR NEVER! manually start the engine with the main, GFCI or auxiliary circuit breakers in the ON (closed) position. Figure 41. Voltage Selector Switch 1.
DCA-45SSIU3 (60 Hz) — GENERATOR START-UP PROCEDURE 9. The generator's frequency meter (Figure 44) displays the 50 cycle output frequency in HERTZ. 13. The engine oil pressure gauge (Figure 48) will indicate the oil pressure (kg/cm2) of the engine. Under normal operating conditions the oil pressure is between 28 ~71 psi (193 ~490 kPa). Figure 44. Frequency Meter (Hz) Figure 48. Oil Pressure Gauge 10. The generator's voltage meter (Figure 45) displays the 14.
DCA-45SSIU3 (60 Hz) — GEN. START-UP PROCEDURE/SHUTDOWN 16. Turn the main, GFCI, and aux. circuit breakers to the “ON” position (Figure 51). Figure 53. Main, AUX. and GFCI Circuit Breakers (OFF) Figure 51. Main, AUX. and GFCI Circuit Breakers (ON) 17. Observe the generator's ammeter (Figure 52) and verify it reads the anticipated amount of current with respect to the load. The ammeter will only display a current reading if the load is in use. 2.
DCA-45SSIU3 (60 Hz) — MAINTENANCE 10 Hrs DAILY TABLE 14.
DCA-45SSIU3 (60 Hz) — MAINTENANCE Air Removal If air enters the fuel injection system of a diesel engine, starting becomes impossible. After running out of fuel, or after disassembling the fuel system, bleed the system according to the following procedure. To restart after running out of fuel, turn the switch to the “ON” position for 15-30 seconds. Try again, if needed. This unit is equipped with an automatic air bleeding system.
DCA-45SSIU3 (60 Hz) — MAINTENANCE If the generator will be used daily, the battery should normally not require charging. If the generator will be idle (not used) for long periods of time, apply power to the battery charger This generator can be optionally equipped with two 120 VAC, receptacle via commercial power using an power cord of 20 amp input receptacles located on the output terminal adequate size. panel.
DCA-45SSIU3 (60 Hz) — TRAILER MAINTENANCE 8. Tire Size - Indicates the diameter of the tire in inches (10,12,14, etc.), and the width in millimeters This section is intended to provide the user with generic (175,185,205, etc.). The tire diameter must match the trailer service and maintenance information. The service and diameter of the tire rim. maintenance guidelines referenced in this section refer to a wide range of trailers. 9.
DCA-45SSIU3 (60 Hz) — TRAILER MAINTENANCE Brakes Trailer brakes should be inspected the first 200 miles of operation. This will allow the brake shoes and drums to seat properly. After the first 200 mile interval, inspect the brakes every 3,000 miles. If driving over rough terrain, inspect the brakes more frequently. Figure 57 displays the major hydraulic surge brake components that will require inspection and maintenance.
DCA-45SSIU3 (60 Hz) — TRAILER MAINTENANCE Tires/Wheels/Lug Nuts Tires and wheels are a very important and critical components of the trailer. When specifying or replacing the trailer wheels it is important the wheels, tires, and axle are properly matched. CAUTION - EYESIGHT HAZARD Suspension The leaf suspension springs and associated components (Figure 58) should be visually inspected every 6,000 miles for signs of excessive wear, elongation of bolt holes, and loosening of fasteners.
DCA-45SSIU3 (60 Hz) — TRAILER MAINTENANCE Lug Nut Torque Requirements It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows: 1. Start all wheel lug nuts by hand. 2. Torque all lug nuts in sequence (see Figure 59). DO NOT torque the wheel lug nuts all the way down. Tighten each lug nut in 3 separate passes as defined by Table 18. 3.
DCA-45SSIU3 (60 Hz) — TRAILER WIRING DIAGRAM Figure 60. Trailer/Towing Vehicle Wiring Diagram PAGE 44 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — GENERATOR WIRING DIAGRAM Figure 61. Generator Wiring Diagram 1 DCA-45SSIU3 (60 Hz) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — ENGINE WIRING DIAGRAM Figure 62. Engine Wiring Diagram PAGE 46 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — TROUBLESHOOTING (GENERATOR) Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 19 shown below for diagnosis of the Generator. If the problem cannot be remedied, consult our company's business office or service plant. TABLE 19.
DCA-45SSIU3 (60 Hz) — TROUBLESHOOTING (ENGINE) Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 20 (Engine Troubleshooting) as a basic guideline for troubleshooting the Engine. If the problem cannot be remedied, consult our company's business office or service plant. TABLE 20. ENGINE TROUBLESHOOTING SYMPTOM Engine does not star t. POSSIBLE PROBLEM SOLUTION No fuel? Replenish fuel.
DCA-45SSIU3 (60 Hz) — TROUBLESHOOTING (ENGINE) TABLE 20. ENGINE TROUBLESHOOTING (CONTINUED) SYMPTOM Engine revolution is not smooth. Either white or blue exhaust gas is observed. Either black or dark gray exhaust gas is observed. Deficient output. POSSIBLE PROBLEM SOLUTION Fuel filter clogged or dir ty? Clean or change. Air cleaner clogged? Clean or change. Fuel leak due to loose injection pipe retaining nut? Tighten nut. Injection pump malfunctioning? Repair or replace.
DCA-45SSIU3 (60 Hz) — EXPLANATION OF CODE IN REMARKS COLUMN The following section explains the different symbols and remarks used in the Parts section of this manual. Use the help numbers found on the back page of the manual if there are any questions. The contents and part numbers listed in the parts section are subject to change without notice. Multiquip does not guarantee the availibility of the parts listed. Sample Parts List: NO.
DCA-45SSIU3 (60 Hz) — SUGGESTED SPARE PARTS DCA-45SSIU3 (60 HZ) ULTRA-SILENT GENRATOR W/ISUZU BB-4JG1T ENGINE 1 TO 3 UNITS Qty. P/N Description 5 ......... 8943672922 ........ FILTER, OIL 5 ......... 8943692993 ........ FILTER, FUEL, CARTRIDGE 3 ......... 0602046366 ........ ELEMENT, AIR 1 ......... 8941618410 ........ BELT, FAN 1 ......... 0605505070 ........ CAP. FUEL TANK 1 ......... 0602122272 ........ UNIT, OIL PRESSURE 1 ......... 0602123261 ........ UNIT, WATER TEMPERATURE 1 ......... 1518183040 ....
DCA-45SSIU3 (60 Hz) — GENERATOR ASSY. GENERATOR ASSY. PAGE 52 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — GENERATOR ASSY. GENERATOR ASSY. NO. PART NO.
DCA-45SSIU3 (60 Hz) — CONTROL BOX ASSY. CONTROL BOX ASSY. PAGE 54 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — CONTROL BOX ASSY. CONTROL BOX ASSY. NO. PART NO.
DCA-45SSIU3 (60 Hz) — ENGINE & RADIATOR ASSY. ENGINE & RADIATOR ASSY. PAGE 56 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — ENGINE & RADIATOR ASSY. ENGINE & RADIATOR ASSY. NO. PART NO. PART NAME QTY. REMARKS 1 M1923200054 ENGINE ...............................................................1 ........ ISUZU BB-4JG1T PD-04 1-1 8970497081 CARTRIDGE, OIL FILTER ..................................1 ........ REPLACES P/N 0602041214 2 0605000048 RUBBER SUSPENSION 2 3 0030010000 HEX NUT 2 4 0040010000 SPRING WASHER 2 5 0041210000 PLAIN WASHER 2 6 M1923200064 RADIATOR ................................................
DCA-45SSIU3 (60 Hz) — ENGINE & RADIATOR ASSY. ENGINE & RADIATOR ASSY. PAGE 58 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — ENGINE & RADIATOR ASSY. ENGINE & RADIATOR ASSY. NO. PART NO. PART NAME QTY.
DCA-45SSIU3 (60 Hz) — OUTPUT TERMINAL ASSY. OUTPUT TERMINAL ASSY. ADD THE FOLLOWING DIGITS AFTER THE PART NUMBER WHEN ORDERING ANY PAINTED PANEL TO INDICATE COLOR OF UNIT: 1-ORANGE 2-WHITE 3-SPECTRUM GREY 4-SUNBELT GREEN 5-BLACK 6-CATERPILLAR YELLOW 7-CATO GOLD 8-RED THE SERIAL NUMBER MAY BE REQUIRED. PAGE 60 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — OUTPUT TERMINAL ASSY. OUTPUT TERMINAL ASSY. NO. PART NO.
DCA-45SSIU3 (60 Hz) — ENGINE OPERATING PANEL ASSY. ENGINE OPERATING PANEL ASSY. PAGE 62 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — ENGINE OPERATING PANEL ASSY. ENGINE OPERATING PANEL ASSY. NO. PART NO. PART NAME QTY. REMARKS 1 8970444180 STARTER SWITCH .............................................1 ........ REPLACES P/N 0602100009 ....................................................................................... INCLUDES ITEM W/ * 1A 8944024980 KEYS, IGNITION SWITCH 1 * 0602103092 2 PREHEAT LAMP .................................................1 ........
DCA-45SSIU3 (60 Hz) — BATTERY ASSY. BATTERY ASSY. PAGE 64 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — BATTERY ASSY. BATTERY ASSY. NO. PART NO. 1 0602220187 2 M9310500014 3 M9103000304 4 0602220920 5 0040006000 6 M1347200004 7 M1347200104 8 0016910020 9 0040510000 PART NAME QTY. REMARKS BATTERY ............................................................1 ........ 627MFD BATTERY SHEET 1 BATTERY BAND 1 BATTERY BOLT SET ..........................................2 ........
DCA-45SSIU3 (60 Hz) — MUFFLER ASSY. MUFFLER ASSY. PAGE 66 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — MUFFLER ASSY. MUFFLER ASSY. NO. PART NO. 1 M1330100703 2 0016910025 3 M1333001903 4 8943690210 5 M1333200114 6 0039308000 7 0016908035 8 M1330400304 9 M1333300004 10 0016906016 11 0602326090 PART NAME QTY. REMARKS MUFFLER 1 HEX HEAD BOLT 4 EXHAUST PIPE 1 GASKET .............................................................1 ........ REPLACES P/N 0602320101 GASKET 1 HEX NUT 6 HEX HEAD BOLT 4 COVER 1 BRACKET 1 HEX HEAD BOLT 4 U BOLT SET ...................................................
DCA-45SSIU3 (60 Hz) — FUEL TANK ASSY. FUEL TANK ASSY. PAGE 68 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — FUEL TANK ASSY. FUEL TANK ASSY. NO. PART NO. 1 M1363001602 2 0605505070 3 M1363200104 4 M9310500104 5 0016908020 6 0207308000 7 0222100600 8 M9200000003 9 M9200200004 10 0150000018 11 0016906020 12 M1363400104 13 0605515198 14 8943672922 14A 8943692993 15 0016908020 16 0602220911 17 0016908020 18 0191201150 19 0191201500 20 0191301100 21 0605515108 22 0605515109 PART NAME QTY.
DCA-45SSIU3 (60 Hz) — ENCLOSURE ASSY. ENCLOSURE ASSY. ADD THE FOLLOWING DIGITS AFTER THE PART NUMBER WHEN ORDERING ANY PAINTED PANEL TO INDICATE COLOR OF UNIT: 1-ORANGE 2-WHITE 3-SPECTRUM GREY 4-SUNBELT GREEN 5-BLACK 6-CATERPILLAR YELLOW 7-CATO GOLD 8-RED THE SERIAL NUMBER MAY BE REQUIRED. PAGE 70 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — ENCLOSURE ASSY. ENCLOSURE ASSY. NO. PART NO.
DCA-45SSIU3 (60 Hz) — ENCLOSURE ASSY. ENCLOSURE ASSY. ADD THE FOLLOWING DIGITS AFTER THE PART NUMBER WHEN ORDERING ANY PAINTED PANEL TO INDICATE COLOR OF UNIT: 1-ORANGE 2-WHITE 3-SPECTRUM GREY 4-SUNBELT GREEN 5-BLACK 6-CATERPILLAR YELLOW 7-CATO GOLD 8-RED THE SERIAL NUMBER MAY BE REQUIRED. PAGE 72 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — ENCLOSURE ASSY. ENCLOSURE ASSY. NO. PART NO.
DCA-45SSIU3 (60 Hz) — RUBBER SEALS ASSY. RUBBER SEALS ASSY. PAGE 74 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — RUBBER SEALS ASSY. RUBBER SEALS ASSY. NO. PART NO.
DCA-45SSIU3 (60 Hz) — NAMEPLATE AND DECALS ASSY. NAMEPLATE AND DECALS ASSY. PAGE 76 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV.
DCA-45SSIU3 (60 Hz) — NAMEPLATE AND DECALS ASSY. NAMEPLATE AND DECALS ASSY. NO. PART NO. PART NAME QTY. REMARKS 1 M1550000204 DECAL; NOTE .....................................................1 ........ M150O0020 2 M1550001304 DECAL; CAUTION ...............................................1 ........ M150O0130 3 M1550002003 DECAL; GENERATOR CONTROL .......................1 ........ M150O0200 4 M1550002103 DECAL; ENGINE OPERATING ...........................1 ........
Effective: October 1, 2002 PAYMENT TERMS TERMS AND CONDITIONS OF SALE — PARTS 5. Parts must be in new and resalable condition, in the original Multiquip package (if any), and with Multiquip part numbers clearly marked. 6. The following items are not returnable: Terms of payment for parts are net 10 days. FREIGHT POLICY All parts orders will be shipped collect or prepaid with the charges added to the invoice. All shipments are F.O.B. point of origin.
NOTE PAGE 1 DCA-45SSIU3 (60 Hz) — OPERATION AND PARTS MANUAL — REV.
PARTS AND OPERATION MANUAL OPERATION AND PARTS MANUAL HERE'S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING MQ POWER CORPORATE OFFICE 18910 Wilmington Ave. 800-421-1244 FAX: 310-632-2656 Carson, CA 90746 Email: mqpower@multiquip.com Internet: www.mqpower.