Product Manual
MQ62TK SERIES TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #0 (01/30/18) — PAGE 23
CONTROL PANEL COMPONENTS
Figure 6. LOFA EL240 G1H Control Panel
AUX
1
AUX
2
OFF
HOURS
FUSE LOCATED INSIDE PANEL
1
2
3
4
5
6
RUN
START
Figure 6 shows the control panel components. The function
of each component is described below:
1. Coolant Temperature Status Indicator — Indicates
coolant temperature has exceeded its limit. This
condition will cause the engine to shut down.
2. Oil Pressure Status Indicator — Indicates oil
pressure is not within specified limits. This condition
will cause the engine to shut down.
3. Preheat Status Indicator — Indicates glow plug
preheating status. When this LED turns OFF,
preheating is complete and the engine may be started.
4. Charge Indicator — Indicates the charging system
is not working properly. This condition will cause the
engine to shut down.
5. Hour Meter — Displays the number of hours the
machine has been in use.
6. Ignition Switch — To start the engine, insert the
ignition key here and turn counterclockwise to the
START position. To shut down the engine, turn the key
counterclockwise to the OFF position.