Product Manual

MQ62TK SERIES TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #0 (01/30/18) — PAGE 23
CONTROL PANEL COMPONENTS
Figure 6. LOFA EL240 G1H Control Panel
AUX
1
AUX
2
OFF
HOURS
FUSE LOCATED INSIDE PANEL
1
2
3
4
5
6
RUN
START
Figure 6 shows the control panel components. The function
of each component is described below:
1. Coolant Temperature Status Indicator — Indicates
coolant temperature has exceeded its limit. This
condition will cause the engine to shut down.
2. Oil Pressure Status Indicator — Indicates oil
pressure is not within specified limits. This condition
will cause the engine to shut down.
3. Preheat Status Indicator — Indicates glow plug
preheating status. When this LED turns OFF,
preheating is complete and the engine may be started.
4. Charge Indicator — Indicates the charging system
is not working properly. This condition will cause the
engine to shut down.
5. Hour Meter — Displays the number of hours the
machine has been in use.
6. Ignition Switch To start the engine, insert the
ignition key here and turn counterclockwise to the
START position. To shut down the engine, turn the key
counterclockwise to the OFF position.