Specifications
DCA70SSJU4i — LOAD BANK INSTRUCTIONS P/N EE58627 — REV. #1 (03/13/15) — PAGE 9
DC CONTROL SPLIT LOOM HARNESS (ECU,
VOLTAGE SELECTOR SWITCH, ECU AND
CONTROL BOX SIDE
1. Continue routing the free end of the DC Control
split-loom harness through the bottom access hole
(Figure 18) on the Control Box.
Figure 18. DC Control Split-Loom Harness
2. Connect the YELLOW, RED and BROWN wires to
the ECU module (pins 13, 16 and 57 respectively) as
shown in Figure 18 and Table 6.
3. Next, connect the RED wire with the terminal ring to
pin 42 on the Voltage Selector Switch.
4. Connect the GREEN/WHITE wire with the terminal ring
to the Control Box ground point.
DC CONTROL
SPLIT-LOOM
HARNESS
P/N EE58517
RED
VOLTAGE
SELECTOR
SWITCH
TERMINAL
42
GND.
4-PIN
TERMINAL
BLOCK
4
CONTROL BOX
YELLOW
BROWN
FROM TB1
CONTACTOR
J-BOX
ADD IN-LINE
FUSE 10 AMP
3
1
2
ECU 835
PIN-57
PIN-13
GRN/WHT
ACCESS
HOLE
PIN-16
PIN-58
PIN-4
JUMPER
WIRE
RED
SPLICE
RED/WHT
BLK
IN-LINE FUSE INSTALLATION
Reference Figure 18.
1. Insert a 10 AMP fuse into the fuse holder (P/N 303110).
2. Connect one end of the fuse holder wire (Figure 18)
to the 4-pin terminal block located at the rear of the
Control Box to terminal 4 (bottom).
3. Next, using a butt splice connector, connect the other
end of the fuse holder wire to the RED/WHITE wire.
4. Once the wiring has been completed, raise the Control
Panel back onto the cabinet frame and secure by
turning the release knobs clockwise.
DECAL PLACEMENT
1. Place Power Balance decal (P/N EE57143) onto
Control Panel as shown in Figure 19.
2. Next, place Patent Pending decal (P/N EE57145) onto
Control Panel as shown in Figure 19.
Figure 19. Decal Placement
3. Reconnect battery.
OFF
W
U
V
OFF
W-U
V-W
U-V
DECREASE
INCREASE
PSI
OIL PRESS
0
25
50
75
100
°F
WATER TEMP
100
140
180
220
260
VOLTS
BATTERY
6
12
18
24
30
FUEL
E
½
F
RPMX10
SPEED
0
120
150
180
210
60
Engine Started
Shutdown
Pre-Alarm
Series 800 Controller
Alarm
Acknowledge
Screen
Change
Program/
Exit
Option
ECU
PATENT PENDING
PLACE
HERE
PLACE
HERE