Specifications
DCA70SSJU4i — LOAD BANK INSTRUCTIONS P/N EE58627 — REV. #1 (03/13/15) — PAGE 3
ANGLE BRACKET INSTALLATION P/N EE58360
1. Located underneath the voltage selector switch
J-box there should be an existing support angle
bracket (Figure 5).
Figure 5. Mounting Brackets
2. Remove the bottom screws (2) on the existing J-box
support angle bracket as shown in Figure 5.
3. Next, attach angle bracket (P/N EE58360) to the
existing J-box support angle bracket using the
hardware that was removed in step 2.
ANGLE BRACKET INSTALLATION P/N EE58359
1. Using 6MM screw (6) with lock washers and flat
washers, attach angle bracket (P/N EE58359) onto
newly installed angle bracket (P/N EE58360).
2. Tighten all screws securely.
CONTACTOR J-BOX INSTALLATION P/N EE58364
1. Using 6MM screw (4), install Contactor
J-Box (P/N EE58364) (Figure 5) onto angle bracket
P/N EE58359.
RESISTOR LOAD BANK WIRING
There are seven BLACK 10 AWG wires that need to be
connected to Resistor Load Bank P/N (EE58325). Six of
the wires are to be connected to the 12 resistors located
inside the load bank, the remaining wire will be connected
to chassis ground.
Connect the 6 resistor load wires and ground wire as
follows:
1. Place the Resistor Load Bank with the Side-A facing
as shown in Figure 6.
CONTACTOR
J-BOX ASSY.
P/N EE58364
VOLTAGE SELECTOR
SWITCH J-BOX
EXISTING
ANGLE
BRACKET
NEW ANGLE
BRACKET
P/N EE58359
NEW ANGLE
BRACKET
P/N EE58360
EXISTING
SCREW
LOCK WASHER
6MM SCREWS
WITH LOCK/FLAT
W
ASHERS 10 PLACES
Figure 6. Load Bank Connections
2. Insert these seven wires into the 10.5" Load Bank
split-loom harness (P/N EE58635).
3. Once the wires have been inserted into the load bank
split-loom harness secure using tie-wraps.
4. Next, attach the six wires to the Resistor Load Bank as
referenced in Figure 6 and Table 2. Please reference
the labeling and length of each wire.
5. To prevent arcing, tighten all nuts securely.
A1
A2
A3
A4
A5
A6
A12
A11
A10
A9
A8
A7
R1
R2
R3
R4
R5
R6
R12
R11
A10
R9
R8
R7
T3 T2 T1
CONTACTOR
K2
CONTACTOR J-BOX P/N EE58359
SIDE A
RESISTOR LOAD BANK
P/N EE58325
COVER ROOF ASSY. P/N EE58361
10 AWG 12”.5
10 AWG 12”.1
10 AWG 12”.2
10 AWG 11”.7
10 AWG 12”
10 AWG 12”.6
10 AWG 11”.0
SIDE B
GND.
T3 T2 T1
CONTACTOR
K1
Table 2. Resistor Load Bank Wiring
Resistor/GND.
Load Bank
Position
Wire Length (ft.)
Black 10 AWG
R1 A1 12.0
R3 A3 12.6
R5 A5 12.1
R7 A7 12.5
R9 A9 12.2
R11 A11 11.7
GND GND Screw 11.0