Specifications
PAGE 34 — MODULAR LIGHT TOWER — PARTS & OPERATION MANUAL — REV. #3 (06/26/06)
MODULAR LIGHT TOWER — ENGINE PRE-SETUP
WARNING:WARNING:
WARNING:WARNING:
WARNING:
Before Starting
1. Be sure to disconnect the electrical load and switch the
main circuit breaker to the “OFF” position prior to starting
the engine.
2. Never start the engine with any circuit breakers in the
“ON” position.
3. Make sure the light tower/generator is positioned on firm
level ground. Check the lubricating oil level prior to
starting the engine. The engine oil level must be
maintained between two notches on the oil dipstick.
4. When there is not enough lubricating oil, fill the crankcase
with high grade motor oil. Use a high quality detergent
oil classified CC or higher.
5. Check the coolant level in the radiator and sub-tank.
Replenish with antifreeze as necessary. Always maintain
the coolant level between the FULL and LOW markings
on the coolant container. Be sure that the radiator cap is
fastened securely.
CAUTION:CAUTION:
CAUTION:CAUTION:
CAUTION:
z
Check the fuel level on the fuel gauge.
When fuel is low, fill the fuel tank with
clean fresh unleaded automotive
gasoline or diesel fuel.
z
If fuel spillage occurs, completely wipe
up the spilled fuel immediately.
z
NEVER turn the key to the “
START
”
position while the engine is running.
The engine's exhaust contains harmful
emissions.
ALWAYS
ventilate the
exhaust when operating inside tunnels,
excavations or buildings. Direct exhaust
away from nearby personnel.
Starting
NEVER operate the light tower with the engine compart-
ment doors open. Operation with the doors open may cause
insufficient cooling to the unit, and damage may result.
Shutdown
Shut-down the engine as specified in the engine manual
provided with the light tower.
For the starting and operation of
the engine and generator of the
light tower, refer to the appropriate
Operation Manual for your light
tower.
NOTE