Pay close attention to ventilation when
operating the generator in enclosed areas.
The engine exhaust contains noxious
elements.
Indoor Installation
Exhaust gases from gasoline engines are extremely
poisonous. Whenever an engine is installed indoors the
exhaust fumes must be vented to the outside. The engine
should be installed at least two feet from any outside wall.
Using an exhaust pipe which is too long or too small can
cause excessive back pressure which will cause the engine
to heat excessively and possibly burn the valves.
Eliminate the danger of deadly carbon monoxide gas.
Remember that exhaust fumes from any gasoline or diesel
engine are very poisonous if discharged in a closed area. If
the light tower is installed indoors, you must make provisions
for venting the engine exhaust to the outside of the building.
T-Bar and Floodlight Assembly
1. Install and secure T-Bar assembly as shown in Figure 8
using the supplied hardware.
2. Attach and secure the four flood light assemblies to the
T-Bar as shown in Figure 13.